Radiation Dose Reduction in Paranasal Sinus CT
نویسندگان
چکیده
Objectives. To (1) compare the radiation dose of low-dose computed tomography (CT) to that of standard-dose CT, (2) determine the minimum optimal radiation dose for use in patients who need endoscopic sinus surgery, and (3) assess the reliability of iterative model reconstruction. Study Design. Prospective single-institution study. Setting. Tertiary care center. Subjects and Methods. We recruited 48 adults with medically refractory sinusitis. Each patient underwent 4 scans with different CT parameters: 120 kV and 100 mAs (standard dose), 100 kV and 40 mAs (low dose), 100 kV and 20 mAs (very low dose), and 100 kV and 10 mAs (ultra-low dose). All CT scans were reconstructed via filtered backprojection, and ultra-low dose scans were additionally reconstructed through iterative model reconstruction. Radiation dose, image quality, and diagnostic performance were compared among the scans. Results. Radiation doses decreased to 6% (ultra-low dose), 12% (very low dose), and 22% (low dose) of the standarddose CT. The image quality of low-dose CT was similar to that of standard-dose CT. Ultra-low-dose CT with iterative model reconstruction was inferior to standard-dose CT for identifying anatomic structures, except for the optic nerve. All CT scans had 100% agreement for diagnosing rhinosinusitis. Conclusions. With low-dose CT, the radiation dose can be decreased to 22% of that of standard-dose CT without affecting the image quality. Low-dose CT can be considered the minimum optimal radiation for patients who need surgery. Iterative model reconstruction is not useful for assessing the anatomic details of the paranasal sinus on CT.
منابع مشابه
Image Optimization and reduction of radiation dose in CT of the paranasal sinuses
Introduction: Since demand for computed tomography (CT) examinations is growing, patients are exposed more frequently to ionizing radiation. To reduce the dose delivered to patients in each scan, CT technologists can change the image acquisition parameters. However, this reduces image quality. Present study aimed to optimize and reduce radiation dose in a CT of the paranasal si...
متن کاملRadiation dose reduction in paranasal sinus CT using model-based iterative reconstruction.
BACKGROUND AND PURPOSE CT performed with Veo model-based iterative reconstruction has shown the potential for radiation-dose reduction. This study sought to determine whether Veo could reduce noise and improve the image quality of low-dose sinus CT. MATERIALS AND METHODS Twenty patients consented to participate and underwent low- and standard-dose sinus CT on the same day. Standard-dose CT wa...
متن کاملComparison of simulated cone beam computed tomography to conventional helical computed tomography for imaging of rhinosinusitis.
OBJECTIVES/HYPOTHESIS Cone beam computed tomography (CBCT) has emerged as a low radiation dose alternative to traditional computed tomography (CT) to evaluate the paranasal sinuses. The purpose of our study was to determine how often clinically important findings would be missed if CBCT was used routinely for sinus imaging. STUDY DESIGN Retrospective review. METHODS We evaluated all maxillo...
متن کاملUniversal sinus computed tomography protocol for diagnostic imaging and intraoperative navigation
BACKGROUND Sinus computed tomography (CT) is performed for the diagnosis of paranasal sinus disease and to assess response to medical therapy. In addition, sinus CT is used for intraoperative imaging guidance. Multiple CTs increase cost and radiation exposure. OBJECTIVE To determine potential cost savings and radiation dose reduction that result from the use of a single universal sinus CT pro...
متن کاملبررسی دقت تشخیصی Limited Screening CT و مقایسه با CT استاندارد در تشخیص سینوزیت
Background and purpose : Çoronal ÇT scan of paranasal sinuses with contiguous images is the gold standard technique in diagnosis of sinusitis. Çonsidering the expense and high dose of radiation in conventional ÇT scan, clinical measurements and simple radiography is not enough sensitive and specific, some workers have suggested limited screening (non contiguous) instead of conventional ÇT ima...
متن کامل