Mapping of Autogenous Saphenous Veins as an Imaging Adjunct to Peripheral MR Angiography in Patients with Peripheral Arterial Occlusive Disease and Peripheral Bypass Grafting: Prospective Comparison with Ultrasound and Intraoperative Findings

نویسندگان

  • Ann-Marie Bintu Munda Jah-Kabba
  • Guido Matthias Kukuk
  • Dariusch Reza Hadizadeh
  • Frank Träber
  • Arne Koscielny
  • Mustapha Sundifu Kabba
  • Frauke Verrel
  • Hans Heinz Schild
  • Winfried Albert Willinek
چکیده

BACKGROUND Mapping of the great saphenous vein is very important for planning of peripheral and coronary bypass surgery. This study investigated mapping of the great saphenous vein as an adjunct to peripheral MR angiography using a blood pool contrast agent in patients who were referred for evaluation of peripheral arterial occlusive disease and bypass surgery. METHODS 38 patients with peripheral arterial occlusive disease (21 men; mean age: 71 years, range, 44-88 years) underwent peripheral MR angiography using the blood pool contrast agent Gadofosveset trisodium. Apart from primary arterial assessment images were evaluated in order to determine great saphenous vein diameters at three levels: below the saphenofemoral junction, mid thigh and 10 cm above the knee joint (usability: diameter range: >3 and <10 mm at one level and >3.5 and <10 mm at a neighboring level). Duplex ultrasound was performed by an independent examiner providing diameter measurements at the same levels. Additionally, vessel usability was determined intraoperatively by the vascular surgeon during subsequent bypass surgery. RESULTS Mean venous diameters for MR angiography/duplex ultrasound were 5.4±2.6/5.5±2.8 mm (level 1), 4.7±2.7/4.6±2.9 mm (level 2) and 4.4±2.2/4.5±2.3 mm (level 3), respectively, without significant differences between the modalities (P = 0.207/0.806/0.518). Subsequent surgery was performed in 27/38 patients. A suitable saphenous vein was diagnosed in 25 and non-usability was diagnosed in 2 of the 27 patients based on MR angiography/duplex ultrasound, respectively. Usability was confirmed by intraoperative assessment in all of the 24 patients that received a venous bypass graft in subsequent bypass surgery. In 1 case, in which the great saphenous vein was assessed as useable by both MR angiography and duplex ultrasound, it was not used during subsequent bypass surgery due to the patients clinical condition and comorbidities. CONCLUSION Simultaneous mapping of the great saphenous vein as an imaging adjunct to peripheral MR angiography with a blood pool contrast agent is an alternative to additive duplex ultrasound in patients undergoing subsequent peripheral bypass grafting.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The value of pre-operative ultrasound mapping of the greater saphenous vein prior to 'closed' in situ bypass operations.

OBJECTIVE The aim of this study was to test pre-operative ultrasound mapping for the detection of duplications and narrow vein segments of the greater saphenous vein (GSV) used as bypass for occlusive arterial disease surgery. PATIENTS AND METHODS In 44 patients pre-operative ultrasound findings of duplications and lumen assessment of GSV were compared to the per-operative findings. RESULTS...

متن کامل

Initial experience with the benefits of intraoperative angiography in surgery for peripheral arterial occlusive disease.

BACKGROUND This preliminary investigation evaluated the procedures for intraoperative angiography-assisted peripheral vascular revascularization in a teaching hospital. METHODS Between August 2000 and July 2001, intraoperative angiography with or without intervention was applied during surgery for peripheral arterial occlusive disease (PAOD) in 11 patients. Intraoperative angiography was empl...

متن کامل

Patency of Reverse Saphenous Vein Graft for Revascularization of Lower Limbs in Diabetic Patients

The clinical expression of vascular disease in the lower extremities of diabetics varies from asymptomatic to critical limb ischemia [1]. Ulcers and gangrene may develop, ultimately leading to amputation or even to death. In the diabetic population, the risk of vascular disease increases with age, duration of diabetes, and presence of peripheral neuropathy. The true prevalence of Peripheral Art...

متن کامل

Use of multidetector computed tomography angiography of upper limb circulation in patients undergoing coronary artery bypass grafting surgery

OBJECTIVE This study aimed to evaluate the bilateral forehand circulation using a 64-channel multidetector computed tomography (MDCT) as a noninvasive method to define criteria for an upper extremity arterial anatomy and pathology prior to the use of arterial conduits. MATERIALS AND METHODS Fifty-five patients with coronary artery disease who underwent total arterial coronary artery bypass gr...

متن کامل

MR angiography illustrates runoff in diabetic patients

Foot complications associated with diabetes are the most common cause of nontraumatic lower extremity amputations in the industrialized world. Research indicates that the risk of lower limb amputation is 15 to 46 times higher in diabetic patients than in those without the disease.1 Common risk factors include peripheral neuropathy, structural foot deformity, infection, ulceration, and periphera...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2014