Time-Optimized High-Resolution Readout-Segmented Diffusion Tensor Imaging
نویسندگان
چکیده
Readout-segmented echo planar imaging with 2D navigator-based reacquisition is an uprising technique enabling the sampling of high-resolution diffusion images with reduced susceptibility artifacts. However, low signal from the small voxels and long scan times hamper the clinical applicability. Therefore, we introduce a regularization algorithm based on total variation that is applied directly on the entire diffusion tensor. The spatially varying regularization parameter is determined automatically dependent on spatial variations in signal-to-noise ratio thus, avoiding over- or under-regularization. Information about the noise distribution in the diffusion tensor is extracted from the diffusion weighted images by means of complex independent component analysis. Moreover, the combination of those features enables processing of the diffusion data absolutely user independent. Tractography from in vivo data and from a software phantom demonstrate the advantage of the spatially varying regularization compared to un-regularized data with respect to parameters relevant for fiber-tracking such as Mean Fiber Length, Track Count, Volume and Voxel Count. Specifically, for in vivo data findings suggest that tractography results from the regularized diffusion tensor based on one measurement (16 min) generates results comparable to the un-regularized data with three averages (48 min). This significant reduction in scan time renders high resolution (1 × 1 × 2.5 mm(3)) diffusion tensor imaging of the entire brain applicable in a clinical context.
منابع مشابه
Diffusion imaging in humans at 7T using readout-segmented EPI and GRAPPA.
Anatomical MRI studies at 7T have demonstrated the ability to provide high-quality images of human tissue in vivo. However, diffusion-weighted imaging at 7T is limited by the increased level of artifact associated with standard, single-shot, echo-planar imaging, even when parallel imaging techniques such as generalized autocalibrating partially parallel acquisitions (GRAPPA) are used to reduce ...
متن کاملDetermination of Fiber Direction in High Angular Resolution Diffusion Images using Spherical Harmonics Functions and Wiener Filter
Diffusion tensor imaging (DTI) MRI is a noninvasive imaging method of the cerebral tissues whose fibers directions are not evaluated correctly in the regions of the crossing fibers. For the same reason the high angular resolution diffusion images (HARDI) are used for estimation of the fiber direction in each voxel. One of the main methods to specify the direction of fibers is usage of the spher...
متن کاملMR-based and Optical Prospective Motion Correction for High Resolution DWI with RS-EPI
Introduction: Recently, multiple approaches have been proposed to perform motion correction for diffusion imaging using optical tracking with cameras [1,2] or using MR-based methods which perform real-time registration between volumes [3-5]. In this study, we demonstrate the application of and compare both optical and MR-based motion correction to high-resolution diffusion-weighted imaging usin...
متن کاملSelf-navigated interleaved spiral (SNAILS): application to high-resolution diffusion tensor imaging.
A fat-saturated twice-refocused spin echo sequence was implemented on a GE Signa 1.5-T whole-body system for diffusion-weighted imaging. Data were acquired using an analytically designed interleaved variable-density (VD) spiral readout trajectory. This flexible design algorithm allowed real-time prescription on the scanner. Each interleaf of the VD spiral oversampled the center of k-space. The ...
متن کاملHigh-resolution, Anatomically-accurate Diffusion-weighted Imaging of Orbital and Sinonasal Lesions with RESOLVE
Diffusion-weighted imaging is a core sequence in clinical routine imaging for many anatomical regions including the brain, abdomen, breasts, and pelvis [1, 2]. Conventionally, diffusion-weighted imaging is acquired using a single-shot diffusion-weighted echo planar imaging (EPI) sequence with the primary advantages of insensitivity to motion-induced phase errors and relatively short acquisition...