Trisodium citrate 4%--an alternative to heparin capping of haemodialysis catheters.

نویسندگان

  • Charmaine E Lok
  • Debra Appleton
  • Cynthia Bhola
  • Brian Khoo
  • Robert M A Richardson
چکیده

BACKGROUND Central venous catheters (CVCs) continue to be used at a high rate for dialysis access and are frequently complicated by thrombus-related malfunction. Prophylactic locking with an anticoagulant, such as heparin, has become standard practice despite its associated risks. Trisodium citrate (citrate) 4% is an alternative catheter locking anticoagulant. METHODS The objective was to prospectively study the clinical effectiveness, safety and cost of citrate 4% vs heparin locking by comparing rates of CVC exchanges, thrombolytic use (TPA) and access-associated hospitalizations during two study periods: heparin period (HP) (1 June 2003-15 February 2004) and Citrate Period (CP) 15 March-15 November 2004. Incident catheters evaluated did not overlap the two periods. RESULTS There were 176 CVC in 121 patients (HP) and 177 CVC in 129 patients (CP). The event rates in incident CVC were: CVC exchange 2.98/1000 days (HP) vs 1.65/1000 days (CP) (P = 0.01); TPA use 5.49/1000 (HP) vs 3.3/1000 days (CP) (P = 0.002); hospitalizations 0.59/1000 days (HP) vs 0.28/1000 days (CP) (P = 0.49). There was a longer time from catheter insertion to requiring CVC exchange (P = 0.04) and TPA (P = 0.006) in the citrate compared with the heparin lock group. Citrate locking costs less than heparin locking but a formal economic analysis including indirect costs was not done. CONCLUSION Citrate 4% has equivalent or better outcomes with regards to catheter exchange, TPA use and access-related hospitalizations compared with heparin locking. It is a safe and less expensive alternative. Randomized trials comparing these anticoagulants with a control group would definitively determine the optimal haemodialysis catheter locking solution.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Trisodium citrate induced protein precipitation in haemodialysis catheters might cause pulmonary embolism.

BACKGROUND The locking anticoagulant plays a decisive role in the patency of central venous catheters (CVCs) used for haemodialysis. During injection, the hydraulic effects inevitably cause lock solution to spill into the systemic circulation. Density differences between whole blood (WB) and the lock solution cause further gravity-induced seepage of lock solution. This is followed by an influx ...

متن کامل

Reduction of biofilm formation with trisodium citrate in haemodialysis catheters: a randomized controlled trial.

BACKGROUND Formation of an intraluminal microbial biofilm is noted to play a significant role in the development of catheter-related infections (CRIs). Recently, it has been demonstrated that trisodium citrate (TSC) has superior antimicrobial effects over heparin for catheter locking. In this randomized controlled trial, we compared the influence of catheter locking with heparin and TSC on the ...

متن کامل

Estimation of trisodium citrate (Citra-Lock) remaining in central venous catheters after the interdialytic interval.

Infection of central venous catheters used for haemodialysis remains an important cause of morbidity and mortality [1]. Patency of the catheters can be maintained between dialyses by a heparin lock, but this has no antibacterial activity. Sodium citrate, especially at higher concentrations, is an anticoagulant with intrinsic antibacterial activity [2]. However, citrate inadvertently entering th...

متن کامل

Sodium citrate 4% locking solution for central venous dialysis catheters--an effective, more cost-efficient alternative to heparin.

BACKGROUND Thrombosis of the central venous haemodialysis catheter compromises dialysis adequacy and catheter survival. Heparin containing catheter-locking solution has been associated with bleeding, interferes with INR (prothrombin time/international normalized ratio) measurements and is costly. Sodium citrate has been used successfully as a catheter-locking solution, but long-term experience ...

متن کامل

Comparison of trisodium citrate and heparin as catheter-locking solution in hemodialysis patients.

INTRODUCTION The high incidence of patients beginning dialysis treatment with venous catheters, as well as the growing number of patients with permanent catheter access, has increased catheter- related blood infections and their consequences. Thus the search for substances with anticoagulant properties that also prevent catheter contamination is necessary. OBJECTIVE This study aimed at compar...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association

دوره 22 2  شماره 

صفحات  -

تاریخ انتشار 2007