Identification of simulated periapical diseases using five different diagnostic imaging methods
نویسندگان
چکیده
Objectives: To assess and compare five diagnostic imaging methods used in the identification of periapical diseases, of different diameters, mechanically simulated. Methods: The sample of the present study consisted of 12 dried human mandibles. Digital panoramic radiography, conventional and digital periapical radiography (charged couple device and photo-stimulable phosphor plate), and high-resolution cone beam computed tomography (CBCT) were previously performed to exclude regions presenting periapical lesions or similar conditions, which then formed the control and experimental groups. Then, periapical diseases were progressively produced with drills of different diameters, thus creating lesions of different sizes. The different image diagnosis methods were applied after each lesion produced. The data were assessed using the Kappa test, ROC curve graphs and Cochran’s Q test. The significance level was set at 0.05. Results: The images obtained with conventional film and digital panoramic radiography showed the worse results (0.65 and 0.55, respectively), and statistically significant differences compared to the controls (p < 0.05) for lesions artificially produced with #6 drill. With regard to high-resolution CBCT, the area values were found to be high for all lesion sizes. Conclusion: Conventional periapical radiography and digital panoramic radiography did not provide satisfactory images for the identification of incipient periapical diseases. The highresolution CBCT showed high accuracy in the diagnosis of periapical diseases in both regions evaluated, and proved to be the most reliable method for the identification of initial periapical diseases (1.8 mm). © 2016 Sociedade Portuguesa de Estomatologia e Medicina Dentária. Published by Elsevier España, S.L.U. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). ∗ Corresponding author. E-mail address: [email protected] (E.M. Villoria). http://dx.doi.org/10.1016/j.rpemd.2016.08.002 1646-2890/© 2016 Sociedade Portuguesa de Estomatologia e Medicina Dentária. Published by Elsevier España, S.L.U. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). Document downloaded from http://www.elsevier.es, day 25/11/2017. This copy is for personal use. Any transmission of this document by any media or format is strictly prohibited.
منابع مشابه
Image enhancement of digital periapical radiographs according to diagnostic tasks
PURPOSE This study was performed to investigate the effect of image enhancement of periapical radiographs according to the diagnostic task. MATERIALS AND METHODS Eighty digital intraoral radiographs were obtained from patients and classified into four groups according to the diagnostic tasks of dental caries, periodontal diseases, periapical lesions, and endodontic files. All images were enha...
متن کاملCone-beam computed tomography versus digital periapical radiography in the detection of artificially created periapical lesions: A pilot study of the diagnostic accuracy of endodontists using both techniques
PURPOSE The aim of this study was to compare the diagnostic accuracy of previously trained endodontists in the detection of artificially created periapical lesions using cone-beam computed tomography (CBCT) and digital periapical radiography (DPR). MATERIALS AND METHODS An ex vivo model using dry skulls was used, in which simulated apical lesions were created and then progressively enlarged u...
متن کاملImpact of Photon Spectra on the Sensitivity of Polymer Gel Dosimetry by X-Ray Computed Tomography
Introduction: The purpose of the current study was to investigate the effect of X-ray spectra on the sensitivity of a polymer gel dosimeter imaged with a conventional computed tomography (CT) scanner. Material and Methods: The whole process of CT imaging of an irradiated polymer gel was simulated by MCNPX Monte Carlo (MC) code. The imaging of polyacrylamide gel was accomplished by means of a co...
متن کاملDiagnostic accuracy of small volume cone beam computed tomography and intraoral periapical radiography for the detection of simulated external inflammatory root resorption.
AIM To compare in an ex vivo model the ability of digital intraoral radiography and cone beam computed tomography (CBCT) to detect simulated external inflammatory root resorption lesions, and to investigate the effect of altering the degree of rotation of the CBCT scanners X-ray source and imaging detector on the ability to detect the same lesions. METHODOLOGY Small and large simulated extern...
متن کاملAssessment of the Wavelet Transform for Noise Reduction in Simulated PET Images
Introduction: An efficient method of tomographic imaging in nuclear medicine is positron emission tomography (PET). Compared to SPECT, PET has the advantages of higher levels of sensitivity, spatial resolution and more accurate quantification. However, high noise levels in the image limit its diagnostic utility. Noise removal in nuclear medicine is traditionally based on Fourier decomposition o...
متن کامل