Facilitation of transvenous lead extraction using site-specific delivery of electrosurgical energy

نویسندگان

  • John N. Catanzaro
  • Menekham Zviman
  • Aravindan Kolandaivelu
  • Saman Nazarian
  • Henry Halperin
  • Ronald D. Berger
  • Jeffrey A. Brinker
  • Alan Cheng
چکیده

Introduction Excimer laser energy is often required to extract chronically indwelling pacemaker and defibrillator leads from the vasculature and myocardium. This technique can be associated with vascular and right ventricular (RV) injuries. We sought to develop a safer, more effective method by applying site-specific delivery of electrosurgical energy (EE). Methods Utilizing a polyacrylamide gel model to simulate soft tissue density, active and passive fixation defibrillator and pacemaker leads were implanted and manually extracted with and without EE delivered to the cathode. The amount of force required for complete removal was measured using a force transducer. The procedure was then repeated in an acute pig model to demonstrate proof of safety. Post mortem gross and histologic specimens were collected from the implantation site. Results In the gel model, the force required for extraction, using manual traction in the active (83.7 g) and passive (74.6 g) fixation ICD leads, was reduced by 37.8% and 33.5%, respectively with EE (both p < 0.01). The force required for extraction, using manual traction in the active (85.2 g) and passive (71.9 g) fixation pacemaker leads, was reduced by 64.4% and 42.6%, respectively with EE (both p < 0.01). In an acute implantation pig model using an active fixation lead, delivery of EE to the cathode (n = 6) reduced the force required to manually extract the lead (140 g +/- 32.5 versus 82 g +/- 14.7, p = 0.03). Post mortem analysis of the RV displayed formation of an epicardial hemorrhagic lesion that was also present after manual traction and EE. There was absence of pericardial effusion, perforation, and ventricular arrhythmia. Conclusions Site-specific delivery of EE to areas of exposed metal along the lead decreased the force necessary for lead extraction in an in vitro and in vivo model. Further studies are needed to evaluate its application in clinical care.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ffect of Chlorhexidine on Prevention of Local Infection in Temporary Transvenous Pacemaker Catheter Site

Background and Objectives: The local infection of temporary transvenous pacemaker catheter site is a common hospital acquired infections. This study aimed to assess the effect of the Chlorhexidine Glaciate 2% on prevention of local infection on temporary transvenous pacemaker catheter site. Materials and Methods: In this 7-month randomized controlled trial, 100 patients having temporary transve...

متن کامل

Transvenous Lead Extraction via the Inferior Approach Using a Gooseneck Snare versus Simple Manual Traction

BACKGROUND AND OBJECTIVES The number of patients with cardiac implantable electronic devices needing lead extraction is increasing for various reasons, including infections, vascular obstruction, and lead failure. We report our experience with transvenous extraction of pacemaker and defibrillator leads via the inferior approach of using a gooseneck snare as a first-line therapy and compare extr...

متن کامل

Extraction of Some Divalent Metal Ions (Cadmium, Nickel and Lead) from Different Tea and Rice Samples Using Ghezeljeh Nanoclay (Geleh-Sar-Shoor) as a New Natural Sorbent

This article presents the method of extraction-preconcentration of Lead, Cadmium, and Nickel ions from food samples using the Ghezeljeh montmorillonite nanoclay (Geleh-Sar-Shoor) as a new native adsorbent in batch single component systems. The extraction-preconcentration of heavy metals were carried out by applying the solid phase extraction (SPE) method followed by atomic abs...

متن کامل

Outcomes of Transvenous Lead Extraction for Cardiovascular Implantable Electronic Device Infections in Patients With Prosthetic Heart Valves.

BACKGROUND Lead-related or valve-related endocarditis can complicate cardiovascular implantable electronic device (CIED) infection in patients with both CIED and prosthetic valves. The objective of this study was to determine the outcomes of transvenous lead extraction for CIED infection in patients with prosthetic valves. METHODS AND RESULTS We retrospectively screened 794 transvenous lead e...

متن کامل

Removal of a chronically implanted active-fixation coronary sinus pacing lead using the Cook Evolution(C) lead extraction sheath.

Case report An 80-year-old man with an implanted resynchronization therapy pacemaker device was referred to our institution in October 2011 to perform a transvenous lead and generator removal for a severe pocket infection. As left ventricular pacing lead, an unipolar activefixation coronary sinus (CS) lead (Attain StarFix 4195OTW,Medtronic Inc.), positioned in a lateral coronary vein, had been ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2014