Rupture of extra-corporeal circuit tubing during cardiopulmonary bypass.

نویسندگان

  • Cheemalapati Sai Krishna
  • Palli Venkata Naresh Kumar
  • Soumya Kanta Satpathy
  • Kanteti Ram Mohan
  • Vedangi Ramesh Babu
چکیده

Roller pumps are widely used for cardiopulmonary bypass in developing nations by virtue of proven safety during several years of institutional use and cost effectiveness. However, careful adjustment of roller occlusion is needed because they are known to cause spallation, tubing wear, and the occasional incident of rupture of tubing in the extracorporeal circuit. Rupture of polyvinylchloride tubing in the pump raceway during repair of a ventricular septal defect in a 4-year-old child is discussed. The event was managed by exclusion and replacement of the defective tubing during a short period of arrest. Use of an inappropriate boot pump and failure to detect its inclusion in the bypass circuit was a significant departure from protocol. However, because occlusion settings and duration of perfusion were within acceptable limits, a manufacturing flaw could also have contributed to tubing failure, and the event may or may not have been averted by the use of larger tubing. In conclusion, this incident reiterates the need for adherence to established protocol during assembly of the pump and draws attention to the fact that tubing integrity is not a guarantee and vigilance is warranted to handle its failure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

SMART tubing presents an increased risk of disconnection during extracorporeal circulation.

A number of products exhibiting biocompatible features have been developed for use in extracorporeal blood circuits during cardiopulmonary bypass procedures. While attention has been focused on biocompatibility features of the blood-circuit interface, a number of issues applicable in clinical use of these circuits have arisen. Surface Modifying Additive Technology (SMART; Cobe Cardiovascular, A...

متن کامل

Electrostatic potential generated during extracorporeal pump prime circulation before cardiopulmonary bypass initiation.

The development of electrostatic potentials generated during cardiopulmonary bypass (CPB) procedures using polyvinylchloride (PVC) tubing in conjunction with roller pumps has been previously documented. The resulting damage from the electrostatic discharge (ESD) has been reported to affect gas transfer devices, but details of potential damage to electronic components commonly used during extrac...

متن کامل

Disconnection of Cobe SMARxT tubing from the venous outlet of the Terumo Capiox SX25RX oxygenator during cardiopulmonary bypass.

The use of surface modified, biocompatible tubing in cardiopulmonary bypass has been reported to decrease the inflammatory responses caused by blood contact with the non endothelial surface of poly vinyl chloride (PVC) tubing. The combination of advances in biocompatible tubing and increased affordability resulted in a change to our cardiopulmonary bypass circuit, with the Terumo Capiox SX25 ox...

متن کامل

Laboratory evaluation of a low prime closed-circuit cardiopulmonary bypass system.

We have explored the potential advantages of a low prime closed-circuit cardiopulmonary bypass (CPB) system using a non-human primate model. Although manufacturers have reduced priming volumes in individual CPB components, the standard circuit volume remains high because of the tubing diameter and length necessary for gravity drainage. By replacing gravity drainage with the negative pressure g...

متن کامل

Triboelectric charging and dissipation characteristics of the Maquet Quadrox-D membrane oxygenator.

Triboelectric charging is commonly detected during cardiopulmonary bypass in circuits using roller pumps and PVC tubing. Dissipation of this charging is needed to prevent a spontaneous discharge from occurring. We evaluated the ability of the Quadrox-D (Maquet) to effectively remove the electrostatic charge accumulation, with and without a heater/cooler connection (H/C). A Quadrox-D oxygenator ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The journal of extra-corporeal technology

دوره 40 1  شماره 

صفحات  -

تاریخ انتشار 2008