Bayesian filtering of myoelectric signals.

نویسنده

  • Terence D Sanger
چکیده

Surface electromyography is used in research, to estimate the activity of muscle, in prosthetic design, to provide a control signal, and in biofeedback, to provide subjects with a visual or auditory indication of muscle contraction. Unfortunately, successful applications are limited by the variability in the signal and the consequent poor quality of estimates. I propose to use a nonlinear recursive filter based on Bayesian estimation. The desired filtered signal is modeled as a combined diffusion and jump process and the measured electromyographic (EMG) signal is modeled as a random process with a density in the exponential family and rate given by the desired signal. The rate is estimated on-line by calculating the full conditional density given all past measurements from a single electrode. The Bayesian estimate gives the filtered signal that best describes the observed EMG signal. This estimate yields results with very low short-time variability but also with the capability of very rapid response to change. The estimate approximates isometric joint torque with lower error and higher signal-to-noise ratio than current linear methods. Use of the nonlinear filter significantly reduces noise compared with current algorithms, and it may therefore permit more effective use of the EMG signal for prosthetic control, biofeedback, and neurophysiology research.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Innovative Methodology Bayesian Filtering of Myoelectric Signals

Sanger TD. Bayesian filtering of myoelectric signals. J Neurophysiol 97: 1839 –1845, 2007. First published December 20, 2006; doi:10.1152/jn.00936.2006. Surface electromyography is used in research, to estimate the activity of muscle, in prosthetic design, to provide a control signal, and in biofeedback, to provide subjects with a visual or auditory indication of muscle contraction. Unfortunate...

متن کامل

Removal of ECG Artifacts from Myoelectric Prosthesis Control Signals

Abstract We investigated removal of electrocardiogram (ECG) artifacts from the myoelectric prosthesis control signals, taken from the reinnervated pectoralis muscles of a patient with bilateral amputations at shoulder disarticulation level. The performance of various ECG artifact removal methods including high pass filtering, spike clipping, template subtracting, wavelet thresholding and adapti...

متن کامل

Comparison of signal-to-noise ratio of myoelectric filters for prosthesis control.

A comparison of signal-to-noise ratios and rise times was performed on several myoelectric filters used for muscle-force estimation and prosthesis control. Linear, averaging, and adaptive filters were compared using single as well as multiple electrode pairs (spatial filtering). The filters were matched for having the same rise time (0-95%) and the signal-to-noise ratios were measured off-line ...

متن کامل

Speech Enhancement Using Gaussian Mixture Models, Explicit Bayesian Estimation and Wiener Filtering

Gaussian Mixture Models (GMMs) of power spectral densities of speech and noise are used with explicit Bayesian estimations in Wiener filtering of noisy speech. No assumption is made on the nature or stationarity of the noise. No voice activity detection (VAD) or any other means is employed to estimate the input SNR. The GMM mean vectors are used to form sets of over-determined system of equatio...

متن کامل

Teaching biotechnology through practical cases

Methods Three cases of study and application of biomedical signals are analyzed: a) Development of a multisensorial prosthesis of upper limb commanded by myoelectric signals (sEMG) b) Development of a robotic wheelchair commanded by eye blinks (myoelectric signals sEMG) and by brain signals (EEG) c) Use of myoelectric signals (sEMG) from disabled children to interact with mobile robots in order...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of neurophysiology

دوره 97 2  شماره 

صفحات  -

تاریخ انتشار 2007