Preparation, Characterization, and Analytical Application of Ramipril Membrane-Based Ion-Selective Electrode
نویسندگان
چکیده
The fabrication and electrochemical evaluation of two PVC membrane-based Ion-Selective electrodes responsive for ramipril drug have been proposed. The sensitive membranes were prepared using ramipril-phosphomolibdate and ramipril-tetraphenylborate ion-pair complexes as electroactive sensing materials in plasticized PVC support. The electrodes based on these materials provide near-Nernestian response (sensitivity of 53 +/- 0.5-54 +/- 0.5 mV/concentration decade) covering the concentration range of 1.0 x 10(-2)-1.0 x 10(-5) mol L(-1) with a detection limit of 3.0 x 10(-6)-4.0 x 10(-6) mol L(-1). The suggested electrodes have been successfully used in the determination of ramipril drug in some pharmaceutical formulations using direct potentiometry with average recovery of >96% and mean standard deviation of <3% (n = 5).
منابع مشابه
N-phenylaza-15-crown-5 as Ionophore in PVC-Matrix for Fe2+ - Selective Sensor
The preparation of polymer membrane selective to Iron(II) ion and its application to ion-selectiveelectrode is reported here. PVC membrane contains Iron–selective N-phenylaza-15-crown-5 asionophore. The membrane electrode is highly selective to Iron(II) ion and exhibit good linearresponse over a wide concentration range of 1.0 × 10-2 to 1.0 × 10-6 M with Nernstian slope of29.2 ± 0.6 mV per deca...
متن کاملCu(II) Ion- Selective Membrane Electrode Based on bis(N-salicylidene-3,3'-diamino diphenyl) sulfone
In order to study the Cu(II) ion selective electrode, an optimized membrane was prepared by mixing of 30 mg of PVC powdered, 5 mg of considered ionophore, 60 mg of plasticizer and 5 mg of additive. The sensor showed a near Nernstian response for Cu(II) ions over a concentration range from 1.0×0-6 –1.0×0-2 M with a slope of 28.90.5 mV per concentration decade with a working pH range of 3.5-6.3. ...
متن کاملChromium(III) ion selective electrode based on 2H-1,4-benzothioazine-2,3(4H)dione dioxime as a neutral carrier
A poly(vinyl chloride) membrane based on a new a-dioxime derivative as membrane carrier was prepared andinvestigated as a Cr(III) selective electrode. The electrode exhibits a good potentiometric response for Cr(III)over a wide concentration range 1.0 x 10-6 to 1.0 x 10-1 M with a slope 19.5+0.5 mV/decade and low detectionlimit of 8.9 x 10-7 M. It has a fast response time < 15 s. The best perfo...
متن کاملApplication of a dioxime-PVC electrode to potentiometric studies of Cr(III) ion
A PVC membrane Cr(III) ion selective electrode has been constructed using 2H-1,4-benzothioazine-2,3(4H)dione dioxime (BTD) as membrane carrier. The influence of membrane composition on the electroderesponse was studied. The electrode exhibits a Nernstian response over a Cr(III) concentration range of 1.0 x10 6 to 1.0>< 10-1 M (r = 0.99) with a slope of 19.5 ± 0.5 mV per decade of concentration,...
متن کاملSelective Membrane Electrode for Bromide Ion Based on Aza Pyrilium Ion Derivative as a new Ionophore.
A highly selective electrode for Bromide ion based on aza pyrilium derivative as an excellentionophore is described.The sensor exhibits a good linear response with a slope of ( 60±1 ) mV per decadeover the concentration range of ( 1×10-3 – 9×10-6 M ) , and a detection limit of ( 3×10-6 M ) of Bromideions .The electrode response is independent of pH in the range of(4.0 –9.5).Selectivity coeffici...