Crystalloid and colloid preload for maintaining cardiac output in elderly patients undergoing total hip replacement under spinal anesthesia
نویسندگان
چکیده
The aim of the present study was to compare the effects of colloid and crystalloid preload on cardiac output (CO) and incidence of hypotension in elderly patients under spinal anesthesia (SA). A randomized, double-blinded study was conducted including 47 elderly patients undergoing scheduled total hip replacement (THR), who were randomized to three groups: the control group (C group, n = 15), crystalloid (RS group, n =16) and colloid group (HES group, n = 16). An intravenous preload of 8 mL/kg of either lactated Ringer's solution in the RS group or 6% hydroxyethyl starch in the HES group was infused within 20 min before SA induction, while no intravenous preload was given in the C group. There was a trend of decrease in CO and systolic blood pressure after SA with time in the C group. In the RS and HES groups, CO increased significantly after fluid preloading as compared with baseline (P < 0.01). Thereafter, CO remained higher than baseline until 30 min after SA in the HES group. The change of systolic blood pressure was similar to CO, but no significant difference from baseline was observed in each group. Hypotension occurred in 3 patients in the C group and one each in the RS and HES group, respectively (P = 0.362). Intravascular volume preload with colloid is more effective than crystalloid solution in maintaining CO, which may be improved the hemodynamic stability in elderly patients during SA.
منابع مشابه
The effects of crystalloid and colloid preload on cardiac output in the parturient undergoing planned cesarean delivery under spinal anesthesia: a randomized trial.
BACKGROUND Hypotension after spinal anesthesia for cesarean delivery remains a major clinical problem. Fluid preloading regimens together with vasopressors have been used to reduce its incidence. Previous studies have used noninvasive arterial blood pressure measurement and vasopressor requirements to evaluate the effect of preload. We used a suprasternal Doppler flow technique to measure mater...
متن کاملHydroxyethylstarch compared with modified gelatin as volume preload before spinal anaesthesia for Caesarean section.
We studied 90 patients undergoing elective Caesarean section under spinal anaesthesia who received lactated Ringer's solution 1000 ml with up to 1000 ml of modified gelatin, lactated Ringer's solution 1000 ml with up to 1000 ml of 6% hydroxyethylstarch or only up to 1000 ml of 6% hydroxyethylstarch. Lumbar puncture was performed as soon as 500 ml of the colloid were infused. The incidence of hy...
متن کاملThe control of postoperative pain in elderly patients undergoing total hip replacement under spinal anesthesia
Background The hip replacement surgery is intended to reduce the intensity of joint pain and improve quality of life in patients with arthritic disease. Advanced age is not a limit to surgical treatment for subarachnoid anesthesia, which is well tolerated by elderly patients. The aim of our study is to assess how spinal anesthesia with hyperbaric bupivacaine and buprenorphine and the subsequent...
متن کاملEffect of crystalloid and colloid preloading on uteroplacental and maternal haemodynamic state during spinal anaesthesia for caesarean section.
We have studied the effects of crystalloid 1 litre (lactated Ringer's) or colloid 0.5 litre (hydroxyethyl starch) preloading in 26 healthy parturients undergoing elective Caesarean section under spinal anaesthesia. Maternal placental uterine artery circulation was measured using a pulsed colour Doppler technique with simultaneous measurement of maternal haemodynamics. A high incidence of matern...
متن کاملThe effects of an increase of central blood volume before spinal anesthesia for cesarean delivery: a qualitative systematic review.
UNLABELLED We evaluated in this qualitative systematic review the efficacy of increasing central blood volume on the incidence of hypotension after spinal anesthesia for elective cesarean delivery. Randomized controlled trials investigating any method of increasing central blood volume before the initiation of obstetric spinal anesthesia were sought by using MEDLINE (1966-2000), Embase (January...
متن کامل