Analysis of lipoproteins by capillary zone electrophoresis in microfluidic devices: assay development and surface roughness measurements.

نویسندگان

  • Bruce H Weiller
  • Laura Ceriotti
  • Takayuki Shibata
  • Dietrich Rein
  • Matthew A Roberts
  • Jan Lichtenberg
  • J Bruce German
  • Nico F de Rooij
  • Elisabeth Verpoorte
چکیده

The development of a new assay for lipoproteins by capillary electrophoresis in fused-silica capillaries and in glass microdevices is described in this paper. The separation of low-density (LDL) and high-density (HDL) lipoproteins by capillary zone electrophoresis is demonstrated in fused-silica capillaries with both UV absorption and laser-induced fluorescence detection. This separation was accomplished using Tricine buffer (pH 9.0) with methylglucamine added as a dynamic coating. With UV detection, LDL eluted as a relatively sharp peak with a migration time of approximately 11 min and HDL eluted as a broad peak with a migration time of 12.5 min. Fluorescence detection of lipoproteins stained with NBD-ceramide was used with the same buffer system to give comparable results. Furthermore, fluorescence staining of human serum samples yielded results similar to the fluorescently stained LDL and HDL fractions, showing that this method can be used to quantify lipoproteins in serum samples. The method was also used to detect lipoproteins in glass micro-CE devices. Very similar results were obtained in microdevices although with much faster analysis times, LDL eluted as a sharp peak at approximately 25 s and HDL as a broad peak at slightly longer time. In addition, higher resolution was obtained on chips. To our knowledge, these results show the first separation and detection of lipoproteins in a microfluidic device using native serum samples. Atomic force microscopy was used to characterize the rms surface roughness (Rq) of microfluidic channels directly. Devices with different surface roughness values were fabricated using two different etchants for Pyrex wafers with a polysilicon masking layer. Using 49% HF, the measured roughness is Rq = 10.9 +/- 1.6 nm and with buffered HF (NH4F + HF) the roughness is Rq = 2.4 +/- 0.7 nm. At this level of surface roughness, there is no observable effect on the performance of the devices for this lipoprotein separation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A stability indicating capillary electrophoresis method for analysis of buserelin

A simple and rapid stability indicating method based on capillary zone electrophoresis has been developed and validated for the analysis of buserelin (BUS). The best separations were achieved by using a bare fused silica capillary (75 m i.d.; 65.5 cm total, 57.0 cm effective length), phosphate buffer (pH = 3.00; 26.4 mM), at 35 °C. The sample was hydrodynamically injected at 50 mbar for 5 seco...

متن کامل

A stability indicating capillary electrophoresis method for analysis of buserelin

A simple and rapid stability indicating method based on capillary zone electrophoresis has been developed and validated for the analysis of buserelin (BUS). The best separations were achieved by using a bare fused silica capillary (75 m i.d.; 65.5 cm total, 57.0 cm effective length), phosphate buffer (pH = 3.00; 26.4 mM), at 35 °C. The sample was hydrodynamically injected at 50 mbar for 5 seco...

متن کامل

Determination of Aciclovir and its Related Substance Guanine in Bulk Drug and Tablet Preparation by Capillary Electrophoresis

Two Capillary Zone electrophoresis (CZE) methods were developed in this study, one using an acidic buffer (sodium citrate pH = 2.5) and the other using a basic buffer (sodium tetraborate pH = 9.8). The two methods were compared on the basis of repeatability and reproducibility of results and the CZE method developed with the basic buffer was then selected for further studies. The method was ful...

متن کامل

Evaluation of Acetonitrile Deproteinisation of the Serum Samples for the Analysis of Drugs in Serum Using Capillary Zone Electrophoresis

Deproteinisation with acetonitrile (along with methanol or other reagents) is a useful and rapid technique in analysis of drugs or their metabolites in human serum. In this paper application of this simple technique in biopharmaceutical analysis using capillary electrophoresis (CE) is evaluated. Some drugs with different ionic and protein binding properties were selected and dissolved in human ...

متن کامل

Application of the Phenomenological Model to Electrophoretic Mobility in Mixed Solvent Electrolyte Systems in Capillary Zone Electrophoresis

The phenomenological model of Khossravi and Connors (1992) has been adopted to calculate the electrophoretic mobility of drugs at different concentrations of solvents in a binary mixture. The accuracy and predictability of the model have been evaluated employing 14 experimental data sets by using average percentage mean deviation (APMD). The obtained APMD for correlative and predictive studies ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical chemistry

دوره 74 7  شماره 

صفحات  -

تاریخ انتشار 2002