Neonatal Transcutaneous Carbon Dioxide Monitoring--Effect on Clinical Management and Outcomes.
نویسندگان
چکیده
BACKGROUND This work aimed to compare frequency of blood gas measurements per day of mechanical ventilation, occurrence of extreme blood gas CO2 values, and clinical outcomes among ventilated neonates managed with and without transcutaneous carbon dioxide (PtcCO2) monitors. This work also measures agreement between simultaneous PtcCO2 and blood gas CO2 measurements and ascertains factors that affect agreement. METHODS This is a cohort study with retrospective analysis comparing 5,726 blood gas measurements and clinical outcomes for 123 neonates intubated for >48 h before and after the introduction of transcutaneous carbon-di-oxide monitoring devices in a single tertiary care unit. RESULTS Median (interquartile range) blood gas frequency per mechanical ventilation day was 3.9 (2.6-5.3) and 2.9 (2.1-4.0) before and after PtcCO2 monitoring (P = .002) without differences in clinical outcomes at discharge. After adjusting for confounders using Poisson regression, this difference remained significant. The mean ± 2 SD blood gas-PtcCO2 difference was -5.2 ± 17.3 mm Hg. 64% of simultaneous blood gas-PtcCO2 measurements per subject were within ± 7 mm Hg. Greater bias was noted with arterial sample and during the use of high-frequency ventilation. CONCLUSION Despite only moderate agreement between simultaneous PtcCO2 and blood gas measurements, PtcCO2 monitoring statistically decreased blood gas frequency among ventilated neonates without affecting the duration of mechanical ventilation or clinical outcomes at discharge. The clinical impact of this technology appears to be minimal.
منابع مشابه
End-tidal carbon dioxide and transcutaneous carbon dioxide monitoring during neonatal transport
Abbreviations: CO2, Carbon dioxide; PaCO2, Arterial partial pressure of carbon dioxide; PtcCO2, Transcutaneous partial pressure of carbon dioxide; PetCO2, End-tidal partial pressure of carbon dioxide; NETS, Newborn Emergency Transport Service (Victoria); NICU, Neonatal Intensive Care Unit; PaO2/PAO2 ratio, alveolar-arterial ratio. ADC-FNN Online First, published on April 29, 2005 as 10.1136/adc...
متن کاملMonitoring of end tidal carbon dioxide and transcutaneous carbon dioxide during neonatal transport.
OBJECTIVE To assess the accuracy of measurements of end tidal carbon dioxide (CO2) during neonatal transport compared with arterial and transcutaneous measurements. DESIGN Paired end tidal and transcutaneous CO2 recordings were taken frequently during road transport of 21 ventilated neonates. The first paired CO2 values were compared with an arterial blood gas. The differences between arteria...
متن کاملEffects of the transcutaneous electrode temperature on the accuracy of transcutaneous carbon dioxide tension
AIM The harmful effect of hypocapnia on the neonatal brain emphasizes the importance of monitoring arterial carbon dioxide tension (PaCO2). Transcutaneous monitoring of carbon dioxide (tcPCO2) reduces the need for arterial blood sampling. Drawbacks are high electrode temperature causing risks of skin burning. The aim was to determine the accuracy and precision of tcPCO2 at reduced electrode tem...
متن کاملUse of a Combined SpO2/PtcCO2 Sensor in the Delivery Room
Arterial oxygen saturation (SaO(2)) and partial arterial pressure of carbon dioxide (PaCO(2)) are important respiratory parameters in critically ill neonates. A sensor combining a pulse oximeter with the Stow-Severinghaus electrode, required for the measurement of peripheral oxygen saturation (SpO(2)) and transcutaneous partial pressure of carbon dioxide (PtcCO(2)), respectively, has been recen...
متن کاملRespiratory function monitoring during neonatal emergency transport.
This study reports for the first time the use of a respiratory function monitor in a prospective observational cohort of ventilated babies during transport. All 17 babies achieved target transcutaneous carbon dioxide tension within 15 minutes. Fifteen babies had improved ventilation with changes guided by the respiratory function monitor. The monitor was easy to use and useful.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Respiratory care
دوره 61 1 شماره
صفحات -
تاریخ انتشار 2016