Newborn screening by tandem mass spectrometry (MS-MS)
نویسنده
چکیده
Newborn screening for selected inherited metabolic disorders is a well-established public health measure in most developed countries [1/. The purpose is to identify and properly diagnose individuals in the neonatal period to enable early medical intervention to prevent or significantly reduce clinical symptoms such as mental retardation. Some of the basic criteria for determining which inherited disorders are suitable for newborn screening include: (a) the disorder has a relatively high incidence so that the cost per diagnosed individual is reasonable, (b) an effective and not overly expensive medical treatment is available, (c) a relatively tnexpensive screening test is available that is suitable for high volume testing (i.e., preferably automatable), and (d) the screening test has a very high sensitivity (i.e., a very low rate of false negatives) and high specificity (i.e., a low rate of false positives, all of which require expensive follow-up). The prototype for newborn screening based on these criteria is that for phenylketonuria (PKU), developed >30 years ago and now used for screening >10 million infants a year worldwide [2]. PKU is a relatively common inherited disorder, with a frequency of-i in 12 000. About 97% of patients with PKU have hyperphenylalaninemia due to an inherited deficiency of hepatic phenylalanine hydroxylase, which metabolizes the amino acid phenylalanine to tyrosine. Because phenylalanine is an essential amino acid derived entirely from the diet, treatment by restriction of phenylalanine intake with special formulas and diets makes it possible to lower plasma phenylalanine concentrations sufficiently to prevent mental retardation and to prevent damage to the fetus in maternal PKU [2]. The initial technique for PKU newborn screening involved obtaining blood just before discharge from the hospital by heelstick with the blood absorbed on filter paper, dried, and sent at room temperature to screening laboratories. The approximate phenylalanine concentration in discs cut from the dried blood spots was determined by the Guthrie bacterial inhibition assay, in which phenylalanine overcomes the inhibition of bacterial growth so that the diameter of the bacterial growth around the spot is proportional to the concentration of phenylalanine in the blood. This method has been replaced in many centers by a fluorometric assay for phenylalanine. Effective infrastructures have been established by each state to ensure that the screening is comprehensive and that proper follow-up of positives will both identify false positives and lead to appropriate treatment of the diagnosed PKU patients. In addition to PKU, newborn screening for …
منابع مشابه
Tandem mass spectrometry in newborn screening: a primer for neonatal and perinatal nurses.
Since 1961, newborn screening for errors of metabolism (EM) has improved the diagnosis, treatment and outcome of newborns with an EM. Recently, advances in laboratory technology with tandem mass spectrometry (MS/MS) has increased the identification of newborns with an EM. With a single dried filter paper blood spot (Guthrie R, Susi A. A simple phenylalanine method for detecting PKU in large pop...
متن کاملCost-benefit analysis of universal tandem mass spectrometry for newborn screening.
OBJECTIVE To estimate potential costs and benefits of routinely using tandem mass spectrometry (MS/MS) to screen newborns for inborn errors of metabolism. METHOD Analysis of costs and benefits resulting from use of MS/MS in screening of 32 000 newborn infants using data from the Kaiser Permanente Medical Care Program of Northern California plus other published data. SETTING A large health m...
متن کاملUse of tandem mass spectrometry for multianalyte screening of dried blood specimens from newborns.
BACKGROUND Over the past decade laboratories that test for metabolic disorders have introduced tandem mass spectrometry (MS/MS), which is more sensitive, specific, reliable, and comprehensive than traditional assays, into their newborn-screening programs. MS/MS is rapidly replacing these one-analysis, one-metabolite, one-disease classic screening techniques with a one-analysis, many-metabolites...
متن کاملHigh-throughput assay of 9 lysosomal enzymes for newborn screening.
BACKGROUND There is interest in newborn screening of lysosomal storage diseases (LSDs) because of the availability of treatments. Pilot studies have used tandem mass spectrometry with flow injection of samples to achieve multiplex detection of enzyme products. We report a multiplexing method of 9 enzymatic assays that uses HPLC-tandem mass spectrometry (MS/MS). METHODS The assay of 9 enzymes ...
متن کاملUpdate on newborn dried bloodspot testing for cerebrotendinous xanthomatosis: An available high-throughput liquid-chromatography tandem mass spectrometry method
BACKGROUND Cerebrotendinous xanthomatosis (CTX) is a rare genetic disorder of bile acid synthesis that can cause progressive neurological damage and premature death. Detection of CTX in the newborn period would be beneficial since an effective treatment is available. We previously described a liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) test with potenti...
متن کاملNewborn screening for all identifiable disorders with tandem mass spectrometry is cost effective: supporting arguments.
Tandem mass spectrometry (MS/MS) has become increasingly popular as the preferred technology for detecting inborn errors of metabolism in newborn screening (NBS) programmes. Its sensitivity and specificity for detecting numerous metabolic conditions is well-documented. As a NBS technology, there are continuing questions about whether MS/MS should be utilised to the fullest when such usage may m...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 42 3 شماره
صفحات -
تاریخ انتشار 1996