Utilizing the ultrasensitive Schistosoma up-converting phosphor lateral flow circulating anodic antigen (UCP-LF CAA) assay for sample pooling-strategies

نویسندگان

  • Paul L. A. M. Corstjens
  • Pytsje T. Hoekstra
  • Claudia J. de Dood
  • Govert J. van Dam
چکیده

BACKGROUND Methodological applications of the high sensitivity genus-specific Schistosoma CAA strip test, allowing detection of single worm active infections (ultimate sensitivity), are discussed for efficient utilization in sample pooling strategies. Besides relevant cost reduction, pooling of samples rather than individual testing can provide valuable data for large scale mapping, surveillance, and monitoring. METHOD The laboratory-based CAA strip test utilizes luminescent quantitative up-converting phosphor (UCP) reporter particles and a rapid user-friendly lateral flow (LF) assay format. The test includes a sample preparation step that permits virtually unlimited sample concentration with urine, reaching ultimate sensitivity (single worm detection) at 100% specificity. This facilitates testing large urine pools from many individuals with minimal loss of sensitivity and specificity. The test determines the average CAA level of the individuals in the pool thus indicating overall worm burden and prevalence. When requiring test results at the individual level, smaller pools need to be analysed with the pool-size based on expected prevalence or when unknown, on the average CAA level of a larger group; CAA negative pools do not require individual test results and thus reduce the number of tests. RESULTS Straightforward pooling strategies indicate that at sub-population level the CAA strip test is an efficient assay for general mapping, identification of hotspots, determination of stratified infection levels, and accurate monitoring of mass drug administrations (MDA). At the individual level, the number of tests can be reduced i.e. in low endemic settings as the pool size can be increased as opposed to prevalence decrease. CONCLUSIONS At the sub-population level, average CAA concentrations determined in urine pools can be an appropriate measure indicating worm burden. Pooling strategies allowing this type of large scale testing are feasible with the various CAA strip test formats and do not affect sensitivity and specificity. It allows cost efficient stratified testing and monitoring of worm burden at the sub-population level, ideally for large-scale surveillance generating hard data for performance of MDA programs and strategic planning when moving towards transmission-stop and elimination.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Up-converting phosphor technology-based lateral flow assay for detection of Schistosoma circulating anodic antigen in serum.

Schistosoma sp. circular anodic antigen (CAA) serum concentrations reflect actual worm burden in a patient and are a valuable tool for population screening and epidemiological research. However, for the diagnosis of individual imported schistosomiasis cases, the current enzyme-linked immunosorbent assay (ELISA) lacks sensitivity and robustness. Therefore, a lateral flow (LF) assay was developed...

متن کامل

Sensitivity and Specificity of a Urine Circulating Anodic Antigen Test for the Diagnosis of Schistosoma haematobium in Low Endemic Settings

BACKGROUND Elimination of schistosomiasis as a public health problem and interruption of transmission in selected areas are key goals of the World Health Organization for 2025. Conventional parasitological methods are insensitive for the detection of light-intensity infections. Techniques with high sensitivity and specificity are required for an accurate diagnosis in low-transmission settings a...

متن کامل

Evaluation of banked urine samples for the detection of circulating anodic and cathodic antigens in Schistosoma mekongi and S. japonicum infections: a proof-of-concept study.

In Asia, Schistosoma japonicum is the predominant schistosome species, while Schistosoma mekongi is confined to limited foci in Cambodia and Lao People's Democratic Republic. While the People's Republic of China has been successful in controlling schistosomiasis, the disease remains a major public health issue in other areas. In order to prioritise intervention areas, not only accurate diagnosi...

متن کامل

Feasibility of a Lateral Flow Test for Neurocysticercosis Using Novel Up-Converting Nanomaterials and a Lightweight Strip Analyzer

UNLABELLED Neurocysticercosis is a frequent parasitic infection of the human brain, occurring in most of the world, and requires imaging of the brain to diagnose. To determine the burden of disease and to simplify diagnosis, a field-friendly rapid lateral flow (LF) based antibody screening test was developed. The assay utilizes novel nano-sized up-converting phosphor (UCP) reporter particles in...

متن کامل

Day-to-day fluctuation of schistosome circulating antigen levels in serum and urine of humans infected with Schistosoma mansoni in Burundi.

Day-to-day fluctuations of both circulating anodic antigen (CAA) and circulating cathodic antigen (CCA) in serum and urine were examined simultaneously in a group of Schistosoma mansoni-infected individuals from Burundi and compared with each other and with fecal egg count fluctuations. Significant correlations were found between fecal egg counts and circulating antigens (CAA and CCA) and betwe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2017