An immunoinhibition assay for determination of creatine kinase isoforms in serum.
نویسندگان
چکیده
We report a preliminary evaluation of an immunoinhibition assay for creatine kinase isoform quantification. The procedure employs the monoclonal antibody CKM-G01, which inhibits the native M subunit of creatine kinase. The antibody does not inhibit the M subunit modified by removal of lysine by plasma carboxypeptidase N. Residual activity after treatment with the antibody is therefore due to serum delysinated isoforms. The ratio inhibited/residual activity correlated directly with the ratio tissue/serum isoforms. Analysis of the total imprecision of isoform ratio measurement gave a coefficient of variation between 5.9 and 21.1%. Reference intervals for the ratio were 0.14-0.79 in females and 0.19-0.95 in men (p = 0.0046). Analytical and clinical comparison with alternative isoform procedures gave good results, showing that this assay can be used as alternative to the widely accepted electrophoretic method for measurement of the creatine kinase isoform ratio.
منابع مشابه
Creatine kinase isoenzyme MB determination on the ACA: dependence on serum matrix and other effectors.
Creatine kinase isoenzyme MB catalytic activities in human serum, determined by ACA ion exchange chromatography and immunoinhibition, differ significantly, the correlation coefficient being 0.88. The reasons for this variation are interference of antibodies with the creatine kinase B subunit in the immunoinhibition assay, nonreproducible elution of creatine kinase isoenzyme MB from the ion exch...
متن کاملOptimized bioluminescence assay of creatine kinase and creatine kinase B-subunit activity.
Spectrophotometry of CK-B subunit activity based on immunoinhibition is rapid and convenient. However, the low sensitivity limits clinical applications to serum samples with CK-B activities considerably above normal. A sensitive, but not optimized, bioluminescent assay of CK-B, also based on immunoinhibition, has been described. We improved this method by the use of an ADP concentration saturat...
متن کاملMass concentration and activity concentration of creatine kinase isoenzyme MB compared in serum after acute myocardial infarction.
We compared three current methods (immunoinhibition, "Isomune-CK" immunoprecipitation, and the Tandem-E CKMB II immunoenzymometric assay) for determination of creatine kinase (CK; EC 2.7.3.2) isoenzyme MB in serum. Although results inter-correlated well, the immunoinhibition assay gave higher activity values. Atypical CK forms did not interfere with the immunoprecipitation and immunoenzymometri...
متن کاملA macro creatine kinase isoenzyme in serum of apparently healthy individuals.
Activity of creatine kinase B subunit, as measured by an immunoinhibition assay, is persistently increased in certain healthy, asymptomatic adults, whose values for total CK activity are within normal limits. Serum samples from two such individuals were investigated by electrophoresis, heat inactivation, determination of activation energies, and immunosorption (on protein A). The results demons...
متن کاملAnalytical evaluation of methods for serum creatine kinase-MB. Electrophoresis, immunoinhibition and solid phase separation.
The purpose of this study was to evaluate immunoassay methods for the measurement of serum cardiac creatine kinase isoenzyme (CK-MB) with respect to sensitivity and specificity. The CK-MB electrophoretic assay (Helena Laboratories) was used as the reference. Two principles of immunoassay were included in the evaluation,--immunoinhibition and solid phase separation. The direct immunoinhibition t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- European journal of clinical chemistry and clinical biochemistry : journal of the Forum of European Clinical Chemistry Societies
دوره 32 5 شماره
صفحات -
تاریخ انتشار 1994