Effect of plate working length on plate stiffness and cyclic fatigue life in a cadaveric femoral fracture gap model stabilized with a 12-hole 2.4 mm locking compression plate
نویسندگان
چکیده
BACKGROUND There are several factors that can affect the fatigue life of a bone plate, including the mechanical properties of the plate and the complexity of the fracture. The position of the screws can influence construct stiffness, plate strain and cyclic fatigue of the implants. Studies have not investigated these variables in implants utilized for long bone fracture fixation in dogs and cats. The purpose of the present study was to evaluate the effect of plate working length on construct stiffness, gap motion and resistance to cyclic fatigue of dog femora with a simulated fracture gap stabilized using a 12-hole 2.4 mm locking compression plates (LCP). Femora were plated with 12-hole 2.4 mm LCP using 2 screws per fracture segment (long working length group) or with 12-hole 2.4 mm LCP using 5 screws per fracture segment (a short working length group). RESULTS Construct stiffness did not differ significantly between stabilization techniques. Implant failure did not occur in any of the plated femora during cycling. Mean ± SD yield load at failure in the short plate working length group was significantly higher than in the long plate working length group. CONCLUSION In a femoral fracture gap model stabilized with a 2.4 mm LCP applied in contact with the bone, plate working length had no effect on stiffness, gap motion and resistance to fatigue. The short plate working length constructs failed at higher loads; however, yield loads for both the short and long plate working length constructs were within physiologic range.
منابع مشابه
Stiffness and endurance of a locking compression plate fixed on fractured femur.
The effects of locking screw position (long column fixation--long distance between the nearest screws to the fracture--and short column fixation--short distance between the nearest screws to the fracture) and fracture gap size (1-mm and 8-mm transverse fracture gap) on stiffness and fatigue of fractured femur fixed with a locking compression plate (LCP) were biomechanically evaluated. The stiff...
متن کاملLetter to the editor: Proximal femoral locking plate versus dynamic hip screw for unstable intertrochanteric femoral fractures.
To the Editor: We read with interest the article by Dhamangaonkar et al.1 May the authors clarify the following points. 1. A dynamic hip screw (DHS) with fixed angle locking screws reduces the risk of implant failure, particularly for patients with osteoporotic bone or less stable fracture configurations.2 Why did the authors compare a proximal femoral locking plate with a non-locking 135o DHS?...
متن کاملIs plating of mid-shaft clavicular fractures possible with a conventional straight 3.5 millimeter locking compression plate?
OBJECTIVES Current literature describes improved clinical outcomes and a minor rate of pseudoarthrosis following operatively treated clavicular fractures. We investigated the feasibility of using a standard 3.5 mm AO locking compression plate (LCP) of adequate length for the stabilisation of mid-shaft fractures of the clavicle. METHODS The length and acromial and diaphyseal curvature depths w...
متن کاملImmediate weight bearing of comminuted supracondylar femur fractures using locked plate fixation.
Comminuted supracondylar femur fractures (AO-OTA 33A3) are commonly treated with locked plates. Weight bearing is generally restricted for 6 to 12 weeks until radiologic evidence exists of sufficient callous to support weight bearing. Recent clinical studies have reported high nonunion rates with distal femur locked plates. In an attempt to induce beneficial motion across the fracture site, som...
متن کاملUse of locking plate in combination with dynamic compression plate for repair of tibial fracture in a young horse
Grade 1 open spiral fracture of left tibia in a 1.5 year-old horse was treated using a combination of 4.5 mm locking compression plate (LCP) and a dynamic compression plate applied in a neutralization manner. The open wound was managed postoperatively by regular dressing and lavage. Radiograph at 24 days post-treatment revealed callus formation and at two months complete bridging callus was obs...
متن کامل