Automated sample-scanning methods for radiation damage mitigation and diffraction-based centering of macromolecular crystals.

نویسندگان

  • Mark C Hilgart
  • Ruslan Sanishvili
  • Craig M Ogata
  • Michael Becker
  • Nagarajan Venugopalan
  • Sergey Stepanov
  • Oleg Makarov
  • Janet L Smith
  • Robert F Fischetti
چکیده

Automated scanning capabilities have been added to the data acquisition software, JBluIce-EPICS, at the National Institute of General Medical Sciences and the National Cancer Institute Collaborative Access Team (GM/CA CAT) at the Advanced Photon Source. A `raster' feature enables sample centering via diffraction scanning over two-dimensional grids of simple rectangular or complex polygonal shape. The feature is used to locate crystals that are optically invisible owing to their small size or are visually obfuscated owing to properties of the sample mount. The raster feature is also used to identify the best-diffracting regions of large inhomogeneous crystals. Low-dose diffraction images taken at grid positions are automatically processed in real time to provide a quick quality ranking of potential data-collection sites. A `vector collect' feature mitigates the effects of radiation damage by scanning the sample along a user-defined three-dimensional vector during data collection to maximize the use of the crystal volume and the quality of the collected data. These features are integrated into the JBluIce-EPICS data acquisition software developed at GM/CA CAT where they are used in combination with a robust mini-beam of rapidly changeable diameter from 5 µm to 20 µm. The powerful software-hardware combination is being applied to challenging problems in structural biology.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Macromolecular cryocrystallography--methods for cooling and mounting protein crystals at cryogenic temperatures.

Cryocrystallography is routinely used in macromolecular crystallography laboratories. The main advantage of X-ray diffraction data collection near 100K is that crystals display much less radiation damage than seen at room temperature. Techniques and tools are described to facilitate cryoprotecting and flash-cooling crystals for data collection.

متن کامل

Fast two-dimensional grid and transmission X-ray microscopy scanning methods for visualizing and characterizing protein crystals

A fast continuous grid scan protocol has been incorporated into the Swiss Light Source (SLS) data acquisition and analysis software suite on the macromolecular crystallography (MX) beamlines. Its combination with fast readout single-photon counting hybrid pixel array detectors (PILATUS and EIGER) allows for diffraction-based identification of crystal diffraction hotspots and the location and ce...

متن کامل

Protein microcrystallography using synchrotron radiation

The progress in X-ray microbeam applications using synchrotron radiation is beneficial to structure determination from macromolecular microcrystals such as small in meso crystals. However, the high intensity of microbeams causes severe radiation damage, which worsens both the statistical quality of diffraction data and their resolution, and in the worst cases results in the failure of structure...

متن کامل

Dynamic X-ray diffraction sampling for protein crystal positioning.

A sparse supervised learning approach for dynamic sampling (SLADS) is described for dose reduction in diffraction-based protein crystal positioning. Crystal centering is typically a prerequisite for macromolecular diffraction at synchrotron facilities, with X-ray diffraction mapping growing in popularity as a mechanism for localization. In X-ray raster scanning, diffraction is used to identify ...

متن کامل

Radiation damage to nucleoprotein complexes in macromolecular crystallography

Significant progress has been made in macromolecular crystallography over recent years in both the understanding and mitigation of X-ray induced radiation damage when collecting diffraction data from crystalline proteins. In contrast, despite the large field that is productively engaged in the study of radiation chemistry of nucleic acids, particularly of DNA, there are currently very few X-ray...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of synchrotron radiation

دوره 18 Pt 5  شماره 

صفحات  -

تاریخ انتشار 2011