An algorithm for stereotactic localization by computed tomography or magnetic resonance imaging.

نویسندگان

  • J Dai
  • Y Zhu
  • H Qu
  • Y Hu
چکیده

Stereotactic localization of an intracranial lesion by computed tomography or magnetic resonance imaging requires the use of a head frame that is fixed to the skull of the patient. To such head frames are attached either N-shaped or V-shaped localization rods. Because of patient positioning, the transverse imaging slices may not be parallel to the frame base; a coordinate transformation algorithm that takes this possibility into consideration is crucial. Here we propose such an algorithm for a head frame with V-shaped localization rods. Our algorithm determines the transformation matrix between the image coordinate system of a transverse image and the frame coordinate system. The determining procedure has three steps: (a) calculation of the oblique angles of a transverse image relative to the head frame and calculation of the image magnification factor; (b) determination of the coordinates of four central markers in both coordinate systems; and (c) determination of the 3 x 3 transformation matrix by using the coordinates of the four markers. This algorithm is robust in principle and is useful for improving the accuracy of localization.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bimodal magnetic resonance imaging-computed tomography nanoprobes: A Review

Bimodal imaging combines two imaging modalities in order to benefit from their advantages and compensate the limitations of each modality. This technique could accurately detect diseases for diagnostic purposes. Nanoparticles simultaneously offer diagnostic data via various imaging modalities owing to their unique properties. Moreover, bimodal nanoprobes could be incorporated into theranostic s...

متن کامل

An image fusion study of the geometric accuracy of magnetic resonance imaging with the Leksell stereotactic localization system1

A special acrylic phantom designed for both magnetic resonance imaging (MRI) and computed tomography (CT) was used to assess the geometric accuracy of MRI-based stereotactic localization with the Leksell stereotactic head frame and localizer system. The acrylic phantom was constructed in the shape of a cube, 164 mm in each dimension, with three perpendicular arrays of solid acrylic rods, 5 mm i...

متن کامل

Artifacts of Titanium, Zirconium, and Binary Titanium-Zirconium Abutments in Compute Tomography, Cone Beam Computed Tomography, and Magnetic Resonance Imaging

Aim: The aim of this in vitro study was to evaluate imaging artifacts induced by Titanium, Zirconium, Titanium-Zirconium abutments in CT, MRI and CBCT imaging modalities.Methods: A 4×8mm titanium fixture was inserted in a dry human mandible. Titanium, Zirconium and Titanium–Zirconium abutments measuring 10.5 mm in height are located on the fixture, one by one. Each abutment was scan...

متن کامل

Generating Synthetic Computed Tomography and Synthetic Magnetic Resonance (sMR: sT1w/sT2w) Images of the Brain Using Atlas-Based Method

Introduction: Nowadays, magnetic resonance imaging (MRI) in combination with computed-tomography (CT) is increasingly being used in radiation therapy planning. MR and CT images are applied to determine the target volume and calculate dose distribution, respectively. Since the use of these two imaging modalities causes registration uncertainty and increases department w...

متن کامل

A simple method for evaluating stereotactic accuracy of Magnetic Resonance Imaging and Computed Tomography Imaging in Frame Based Radiosurgery.

PURPOSE To design a simple and reproducible method with minimum uncertainty for evaluating the stereotactic accuracy of Computed Tomography imaging and Magnetic Reso-nance Imaging and to compare the results. METHODS 3D phantom has been designed with 1 mm diameter targets in eight sectors for stereotactic MR imaging and CT imaging. The phantom was connected to Leksell stereotactic frame and th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 46 1  شماره 

صفحات  -

تاریخ انتشار 2001