Effect of contrast material injection duration on arterial enhancement at CT in patients with various cardiac indices: Analysis using computer simulation
نویسندگان
چکیده
Arterial peak enhancement on contrast-enhanced CT (CECT) images is thought to be higher in patients with low cardiac function. Using computer simulations, we tested the hypothesis that the relationship between the cardiac index and the aortic peak CT number (PCTN) is affected by the contrast material (CM) injection duration. We created computer simulation software for the contrast enhancement of various organs and vessels based on the Bae pharmacokinetics model and implemented models for CM transmission within organs and CM diffusion in blood plasma based on the osmotic pressure. Aortic contrast enhancement at coronary- and abdominal CT angiographs (CTA) was simulated for a representative 60-year-old Japanese male 166 cm in height and 65.0 kg in weight. The injection protocol for coronary CTA was: CM dose 45.5 ml, iodine dose, 245 mg/kg body weight (BW); injection duration 8-20 sec in 2-sec increments. For abdominal CTA it was CM dose 74.3 ml; iodine dose 400 mg/kg BW; injection duration 10-40 sec in 5-sec increments. In both protocols the iodine concentration was 350 mgI/ml, osmotic pressure was 590 mOsm/kgH2O, and the cardiac index ranged from 0.1-6.0 l/min/m2. Under all protocols, the aortic PCTN increased as the injection duration decreased and as the cardiac index rose to the cardiac index value. It then decreased as it exceeded the cardiac index value. At coronary CTA, at an injection duration of 8 or 10 sec, the PCTN exceeded 350 Hounsfield units (HU) at a cardiac index from 0.9-5.6 l/min/m2. At an HU value greater than 350, the range of the cardiac index narrowed when the injection duration was 12 sec or longer. On abdominal CTA scans performed with an injection duration of 10-, 15-, or 20 sec, the PCTN exceeded 350 HU at a cardiac index ranging from 0.4-5.3 l/min/m2. When the injection duration ranged from 25-40 sec, there was narrowing of the range of the cardiac index at which the PCTN exceeded 350 HU. For coronary and abdominal CTA, contrast enhancement protocols with shorter injection durations yield a diagnostically adequate aortic PCTN at a wide range of cardiac indices.
منابع مشابه
[Multicenter trial for optimization of bolus tracking settings and contrast material injection protocol in arterial dominant phase of dynamic computed tomography for diagnosis of hepatocellular carcinoma].
Alongside current improvements in the performance of computer tomography (CT) systems, there has been an increase in the use of bolus tracking (BT) to acquire arterial dominant phase images for dynamic CT at optimal timing for characterization of liver focal lesions. However, optimal BT settings have not been established. In the present study, methods of contrast enhancement and BT setting valu...
متن کاملInduction of DNA damage, apoptosis and micronuclei in peripheral blood lymphocytes following injection of contrast media in patients with abdominal CT scan
Background: Medical diagnostic procedures such as X-ray and computed Tomography (CT) scan account for considerable percent of patient's exposure to ionizing radiation. The exposure of cells to Ionization radiation results in induction of DNA damage and chromosomal aberrations. Contrast media (CM) are widely used in diagnostic radiology and CT scan. The aim of this study was to study adverse gen...
متن کاملEffects of High-concentration contrast material and low-voltage CT on contrast for multiphasic CT of the upper abdomen: comparison using the simulation with virtual monochromatic imaging obtained by fast-switch kVp dual-energy CT
OBJECTIVE The purpose of this study was to compare the effects of high-concentration contrast material and low-voltage CT simulated by virtual monochromatic (VM) imaging on contrast enhancement at multiphasic CT of the upper abdomen. METHODS This study included 72 patients who underwent CT during early arterial (EAP), late arterial and portal venous phases after 300-mgI/ml (Group A; 34 patien...
متن کاملFDG-avid portal vein tumor thrombosis from hepatocellular carcinoma in contrast-enhanced FDG PET/CT
Objective(s): In this study, we aimed to describe the characteristics of portal vein tumor thrombosis (PVTT), complicating hepatocellular carcinoma (HCC) in contrast-enhanced FDG PET/CT scan. Methods: In this retrospective study, 9 HCC patients with FDG-avid PVTT were diagnosed by contrast-enhanced fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT), which is a comb...
متن کاملContrast Media in Abdominal Computed Tomography: Optimization of Delivery Methods
OBJECTIVE To provide a systematic overview of the effects of various parameters on contrast enhancement within the same population, an animal experiment as well as a computer-aided simulation study was performed. MATERIALS AND METHODS In an animal experiment, single-level dynamic CT through the liver was performed at 5-second intervals just after the injection of contrast medium for 3 minutes...
متن کامل