The maximal accumulated oxygen deficit method: a valid and reliable measure of anaerobic capacity?
نویسندگان
چکیده
The maximal accumulated oxygen deficit (MAOD) method has been extensively, but unfortunately not very methodically, used; the procedure used to determine the MAOD varies considerably. Therefore, this review evaluates the effect of different numbers and durations of submaximal exercise bouts on the linear power output (PO)-oxygen uptake ((.)VO2) relationship and thus the MAOD. Changing the number and duration of the submaximal exercise bouts substantially influences the calculated MAOD when relatively long submaximal exercise bouts are used and no fixed value of the y-intercept is forced into the linear regression line. This is most likely due to non-linearity of the PO-(.)VO2 relationship for exercise intensities above the lactate threshold (LT). Non-linearity of the PO-(.)VO2 relationship is probably caused by the development of a slow component in (.)VO2 during submaximal exercise at intensities above the LT. Thus, it is important to standardize the number, duration and intensity of submaximal exercise bouts necessary to establish the PO-(.)VO2 relationship. Beyond changing the number and duration of the submaximal exercise bouts, the effect of different supramaximal exercise bouts on the calculated MAOD has been investigated. While it has become clear that different exercise protocols result in relatively similar values of the MAOD, a closer look at individual data suggests that it may be important to choose an exercise protocol that is representative of the athlete's event. The validity of the MAOD method was studied by different authors comparing the MAOD with metabolic measurements of anaerobic adenosine triphosphate (ATP) production. The main limitation with the metabolic measurements of anaerobic ATP production from muscle biopsy data is that the active muscle mass is unknown, which makes it hard to accurately study the validity of the MAOD method. From the studies that evaluated the reliability of the MAOD method it is clear that the MAOD method may not be a reliable measure of anaerobic capacity. From these findings it can be concluded that the MAOD method may have limitations as a valid and reliable measure of anaerobic capacity and needs to be further improved. We suggest the use of 10 x 4 minute submaximal exercise bouts and a fixed value of the y-intercept for the construction of the linear PO-(.)VO2 relationship, after which the MAOD can be determined during a supramaximal exercise protocol specific for the athlete's event. This method will lead to a more robust PO-(.)VO2 relationship and will therefore result in more valid and reliable results.
منابع مشابه
Anaerobic Capacityestimated in A Single Supramaximal Test in Cycling: Validity and Reliability Analysis
The aim was to verify the validity (i.e., study A) and reliability (i.e., study B) of the alternative maximal accumulated oxygen deficit determined using onlya supramaximal effort (MAODALT)to estimate anaerobic capacity [i.e., estimated by the gold standard maximal accumulated oxygen deficit method (MAOD)] during cycling. In study A, the effects of supramaximal intensities on MAODALT and the co...
متن کاملEstimation of accumulated oxygen deficit from accumulated blood lactate concentration during supramaximal running in middle-distance runners
The maximal accumulated oxygen deficit (MAOD), which is the gold standard for anaerobic energy metabolism capacity, requires multiple tests for evaluation that impose a heavy load on subjects. The maximal accumulated blood lactate (ΔbLa) concentration is also a measure of anaerobic energy metabolism capacity, and is related to the accumulated oxygen deficit (AOD). Thus, AOD has been estimated b...
متن کاملAssociation between anaerobic components of the maximal accumulated oxygen deficit and 30-second Wingate test
The purpose of this study was to analyze the relationship between the anaerobic components of the maximal accumulated oxygen deficit (MAOD) and of the 30-second Wingate anaerobic test (30-WAnT). Nine male physical education students performed: a) a maximal incremental exercise test; b) a supramaximal constant workload test to determine the anaerobic components of the MAOD; and c) a 30-WAnT to m...
متن کاملThe Relationship Between Peak Oxygen Consumption and Pulmonary Function Indices: Measured by Spirometry and Allometry Equation in Male Students
Purpose: Allometry is a method to express the relationship between physiological and anatomical variables. It can be used to measure the vital capacity through mathematical equations. This study aimed at evaluating lung function indices to estimate the maximal aerobic power by respiratory gas analysis device and the allometric equation. Methods: This study was a descriptive and correlational r...
متن کاملEffect of 30°c heat on the anaerobic capacity of heat acclimatised athletes.
The main finding of this study was that for heat acclimatised athletes, there was no significant difference (p=0.58) in anaerobic capacity for temperate (21.8 ± 0.5 °C; 52 ± 5 % relative humidity) compared with warm conditions (29.6 ± 0.5 °C; 51 ± 9 % relative humidity). Anaerobic capacity was estimated using the maximal accumulated oxygen deficit (MAOD) during constant intensity cycling at 120...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Sports medicine
دوره 40 4 شماره
صفحات -
تاریخ انتشار 2010