Label-free detection of surface markers on stem cells by oblique-incidence reflectivity difference microscopy.

نویسندگان

  • Kai-Yin Lo
  • Yung-Shin Sun
  • James P Landry
  • Xiangdong Zhu
  • Wenbin Deng
چکیده

Conventional fluorescence microscopy is routinely used to detect cell surface markers through fluorophore-conjugated antibodies. However, fluorophore-conjugation of antibodies alters binding properties such as strength and specificity of the antibody in often uncharacterized ways. Here we present a method using an oblique-incidence reflectivity difference (OI-RD) microscope for label-free, real-time detection of cell surface markers, and apply it to analysis of stage-specific embryonic antigen 1 (SSEA1) on stem cells. Mouse stem cells express SSEA1 on their surfaces, and the level of SSEA1 decreases when the cells start to differentiate. In this study, we immobilized mouse stem cells and non-stem cells (control) on a glass surface as a microarray and reacted the cell microarray with unlabeled SSEA1 antibodies. By monitoring the reaction with an OI-RD microscope in real time, we confirmed that the SSEA1 antibodies bind only to the surface of the stem cells and not to the surface of non-stem cells. From the binding curves, we determined the equilibrium dissociation constant (Kd) of the antibody with the SSEA1 markers on the stem cell surface. Thus, the OI-RD microscope can be used to detect binding affinities between cell surface markers and unlabeled antibodies bound to the cells; this information could be useful for determination of stem cell stages.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Real-Time, Label-Free Detection of Biomolecular Interactions in Sandwich Assays by the Oblique-Incidence Reflectivity Difference Technique

One of the most important goals in proteomics is to detect the real-time kinetics of diverse biomolecular interactions. Fluorescence, which requires extrinsic tags, is a commonly and widely used method because of its high convenience and sensitivity. However, in order to maintain the conformational and functional integrality of biomolecules, label-free detection methods are highly under demand....

متن کامل

Oblique-incidence reflectivity difference microscope for label-free high-throughput detection of biochemical reactions in a microarray format.

We describe a recently developed oblique-incidence reflectivity difference (OI-RD) microscope, a form of polarization-modulated imaging ellipsometer, for label-free-high-throughput detection of biomolecular reactions on DNA and protein microarrays. We present examples of application of this technique to end-point and real-time investigations of DNA-DNA hybridization, antibody-antigen capture, a...

متن کامل

Use of real-time, label-free analysis in revealing low-affinity binding to blood group antigens by Helicobacter pylori.

Infectious diseases are often initiated by microbial adherence that is mediated by the binding of attachment molecules, termed adhesins, to cell surface receptors on host cells. We present an experimental system, oblique-incidence reflectivity difference (OI-RD) microscopy, which allows the detection of novel, low-affinity microbial attachment mechanisms that may be essential for infectious pro...

متن کامل

Detection of One-Bead-One-Compound (OBOC) Combinatorial Library Using Oblique Incidence Reflectivity Difference (OI-RD) Microscopy

The utilization of an Oblique-Incidence Reflectivity Difference (OI-RD) microscope to investigate a OneBead-One-Compound (OBOC) combinatorial chemical library is described. A six thousand random small molecule library was previously prepared for proof-of-principle experiments. This paper describes the initial results of these experiments.

متن کامل

Advancing Label-free Microarray Immunoassays with Protein Capture of Antibodies A Demonstration by Oblique Incidence Reflectivity Difference (OI-RD) Ellipsometry

Oblique Incidence Reflectivity Difference (OI-RD), a system developed by Zhu et al, is a versatile, high-throughput, label-free method for probing reactions of biological molecules printed on standard substrates. However, its sensitivity range is currently not as developed as that of label-based techniques. The effectiveness of using recombinant fusion protein A/G to immobilize antibodies on a ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • BioTechniques

دوره 50 6  شماره 

صفحات  -

تاریخ انتشار 2011