Model-free slice following using the cardiac fat navigator: enhanced gating efficiency for 3D SSFP coronary magnetic resonance angiography
نویسندگان
چکیده
INTRODUCTION Free-breathing coronary MRA (CMRA) typically uses a diaphragm navigator (NAV) for respiratory motion suppression, which is an indirect measure of the respiration-induced cardiac motion (1, 2). Slice tracking (3, 4) can be used to widen the acceptance window to improve navigator efficiency, but relies on a linear motion model to derive heart displacement. A linear correction factor of 0.6 is often used, despite high inter-subject variability (5). Subject dependent motion models have been proposed, but require a separate calibration (6). When the correlation between diaphragmatic and cardiac motion is poor due to hysteresis (7), the effectiveness of NAV gating and the slice tracking is not optimal. The cardiac fat navigator (FATNAV) can provide a direct measurement of bulk cardiac motion using the epicardial fat signal and does not require the use of correction factors (6). This study investigates the effectiveness of cardiac fat navigator slice tracking without correction factors for free-breathing 3D SSFP coronary MRA. MATERIALS AND METHODS Experiments were performed on 5 healthy volunteers (33 ± 11 years) at 1.5T (GE Excite HDx 14.0). Imaging parameters were: TR/TE/FA/BW = 4.7 ms/ 1.8 ms/ 90°/ ±62.5 kHz, resolution = 1.0x1.0x3.0 mm, 32 echoes per heartbeat. A custom navigator gating program was implemented to control data acquisition in real time using the Phase Ordering with Automatic Window Selection (PAWS) algorithm (9), which automatically selects the optimal gating window. The cardiac fat navigator consisted of a spectrally selective axial slab excitation combined with spatial saturation bands to suppress chest wall and a cranial-caudal readout using a 13 cm FOV. The real-time derived displacements were used to prospectively correct the slab position. Each coronary artery was imaged twice: A) using a 5 mm gating window with slice tracking and B) using a 2.5 mm gating window without slice tracking. Image quality was assessed by an experienced reader blinded to the imaging technique using a 5-point scale (0=non-diagnostic 1=poor 2=fair 3=good 4=excellent). RESULTS All experiments were performed successfully. A total of N = 9 coronary artery segments were imaged (5 right (RCA), 2 left anterior descending (LAD), 2 left circumflex (LCX) coronary arteries). Figure 1 shows examples of freebreathing CMRA, demonstrating excellent image quality with negligible motion artifacts. Slice tracking provided similar image quality at higher navigator efficiency. While the difference in image quality score was non-significant (3.4 ± 0.5 vs. 3.4 ± 0.7), slice tracking resulted in significantly higher scanning efficiency (69% vs. 47%, P<0.0005). This represents a 45% relative increase in scanning efficiency or a 28% decrease in scanning time. DISCUSSION AND CONCLUSION The cardiac fat navigator combined with model-free slice tracking allowed an enlarged gating window to increase scan efficiency, without affecting image quality. REFERENCES (1) Wang Y, et al. Radiology 1996;198:55-60. (2) Li D., et al, Radiology. 1996 Dec;201(3):857-63 (3). Danias PG, et al Radiology 1997;203:733–736. (4) Spuentrup E, et al, Invest Radiol 37, 11, 632–636 (5) Keegan J et al. Magn Reson Med. 2002 Mar;47(3):476-81. (6) Manke D, et al Magn Reson Med 2003;50:122–131 (7) Nehrke K, et al. Radiology 2001;220:810-815. (8) Nguyen TD, et al. Magn Reson Med 2003;50:235-241. (9) Jhooti P, et al. Magn Reson Med 2000;43:470-480.
منابع مشابه
Direct monitoring of coronary artery motion with cardiac fat navigator echoes.
Navigator echoes (NAVs) provide an effective means of monitoring physiological motion in magnetic resonance imaging (MRI). Motion artifacts can be suppressed by adjusting the data acquisition accordingly. The standard pencil-beam NAV has been used to detect diaphragm motion; however, it does not monitor cardiac motion effectively. Here we report a navigator approach that directly measures coron...
متن کاملSelf-Gated Free-Breathing 3D Coronary CINE Imaging with Simultaneous Water and Fat Visualization
The aim of this study was to develop a novel technique for acquiring 3-dimensional (3D) coronary CINE magnetic resonance images with both water and fat visualization during free breathing and without external respiratory or cardiac gating. The implemented multi-echo hybrid 3D radial balanced Steady-State Free Precession (SSFP) sequence has an efficient data acquisition and is robust against mot...
متن کاملMR coronary artery imaging with 3D motion adapted gating (MAG) in comparison to a standard prospective navigator technique.
Magnetic resonance coronary angiography (MRCA) has been proven to be feasible for imaging of the proximal and medial portions of the three main coronary arteries. Free breathing techniques allow for high resolution imaging but prolong scan time. This could potentially be shortened by improving the efficiency, robustness and accuracy of the navigator gating algorithm. Aim of this study was to de...
متن کاملMulti-phase coronary magnetic resonance angiography using a 3D cones trajectory
Methods Axial slabs covering the whole heart were imaged on a GE Signa 1.5 T Excite system using a surface coil. Following detection of the cardiac trigger and delay TD (Fig. 2), a 2D sagittal spiral navigator image (3-mm resolution) containing the left ventricle was acquired for respiratory motion tracking. Ten catalyzation cycles were then played out to establish the steady state for 3D cones...
متن کاملRapid and complete coronary arterial tree visualization with magnetic resonance imaging: feasibility and diagnostic performance.
AIMS Current imaging of the coronary arteries with magnetic resonance coronary angiography (MRCA) is restricted to limited coverage of the coronary arterial tree and requires complex planning. We present and evaluate a rapid, single-scan MRCA approach with complete coverage of the coronary arterial tree. METHODS AND RESULTS Fifty-five consecutive patients with suspected coronary artery diseas...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2008