Twenty four hour imaging delay improves viability detection by Tl-201 myocardial perfusion scintigraphy

نویسندگان

  • Zehra Pınar Koç
  • Tansel Ansal Balcı
  • Necati Dağlı
چکیده

OBJECTIVE Since twenty-four-hour imaging by Tl-201 myocardial perfusion scintigraphy has been introduced as an effective additional procedure, the aim of this study was to compare this method's result with only rest redistribution procedure in the diagnosis of myocardial viability. METHODS Thirty patients (Seven female, 23 male; mean: 59.8 ± 10.7, 55.8-63.8 years old) with diagnosis of coronary artery disease were involved in this study. All patients had anamnesis of previous myocardial infarction and/or total occlusion of any main artery in the coronary angiography. Myocardial perfusion scintigraphy with Tl-201 with rest four hour (early) redistribution and 24 hour delayed redistribution protocol were performed to all of the patients. The images were evaluated according to 17 segment basis by an experienced nuclear medicine physician and improvement of a segment by visual interpretation was considered as viable myocardial tissue. RESULTS Viability was found at 52 segments in the early redistribution images and additional 18 segments in the 24 hour delayed redistribution images on segment basis in the evaluation of 510 segments of 30 patients. On per patient basis, among the 26 patients who had viable tissue, 14 (54%) had additional improvement in 24 hour delayed images. Three (12%) patients had viable tissue in only 24 hour delayed images. CONCLUSION Delayed imaging in Tl-201 MPS is a necessary application for the evaluation of viable tissue according to considerable number of patients with additional improvement in 24 hour images in our study, which is restricted to the patients with myocardial infarct.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Twenty four hour imaging delay improves viability detection by Tl - 201 myocardial perfusion

Objective: Since twenty-four-hour imaging by Tl-201 myocardial perfusion scintigraphy has been introduced as an effective additional procedure, the aim of this study was to compare this method’s result with only rest redistribution procedure in the diagnosis of myocardial viability. Methods: Thirty patients (Seven female, 23 male; mean: 59.8 ± 10.7, 55.8-63.8 years old) with diagnosis of corona...

متن کامل

Improved diagnostic performance of thallium-201 myocardial perfusion scintigraphy in coronary artery disease: from planar to single photon emission computed tomography imaging.

BACKGROUND This study was performed to compare Tl-201 myocardial perfusion single photon emission computed tomography (SPECT) with planar scintigraphy in the diagnosis of coronary artery disease (CAD). METHODS Retrospectively, 240 of 3262 patients, with exercise-redistribution Tl-201 myocardial perfusion scintigraphy performed between January 1990 and October 1997, were analyzed to compare Tl...

متن کامل

Serial Myocardial Imaging after a Single Dose of Thallium-201

Although thallium-201 exercise scintigraphy has been established for the detection of myocardial ischemia and viability, little is known regarding the myocardial thallium-201 kinetics during angioplasty. Herein, we report a 77-year old man with angina pectoris, in whom serial myocardial imaging after a single dose of thallium-201 was helpful in identifying not only the culprit lesion and myocar...

متن کامل

Twenty-four-hour Tl-201 delayed scan underestimates myocardial viability in patients with acute myocardial infarction after percutaneous transluminal coronary angioplasty.

BACKGROUND Myocardial viability in area at risk of acute myocardial infarction (AMI) after reperfusion therapy may be underestimated by the 24-hour images due to reverse redistribution (r-RD). METHODS Subjects were 37 AMI patients in whom Tc-99m pyrophosphate (PYP)/Tl-201 dual-isotope SPECT was positive. The 24-hour delayed scan was performed with only a Tl window. One month later, follow up ...

متن کامل

The value and throughput of rest Thallium-201/stress Technetium -99m sestamibi dual-isotope myocardial SPECT.

Myocardial perfusion scintigraphy is an established method in cardiology for the diagnosis and evaluation of coronary artery disease (CAD). Thallium-201 and Tc-99m sestamibi myocardial perfusion imaging has been widely accepted as non-invasive diagnostic procedure for detection of CAD, risk stratification and myocardial viability assessment. But, standard Tl-201 redistribution and same day or 2...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 28  شماره 

صفحات  -

تاریخ انتشار 2013