Characterisation of respiratory motion extracted from 4D MRI
نویسندگان
چکیده
Nuclear Medicine (NM) imaging is currently the most sensitive approach for functional imaging of the human body. However, in order to achieve high-resolution imaging, one of the factors degrading the detail or apparent resolution in the reconstructed image, namely respiratory motion, has to be overcome. All respiratory motion correction approaches depend on some assumption or estimate of respiratory motion. In this paper, the respiratory motion found from 4D MRI is analysed and characterised. The characteristics found are compared with previous studies and will be incorporated into the process of estimating respiratory motion.
منابع مشابه
Design and Fabrication of a Four-Dimensional Respiratory Phantom for Studying Tumor Movement in Radiotherapy with Magnetic Resonance Imaging
Introduction: In radiation therapy, determining the location of the tumor accurately during irradiation is one of the most important requirements. However, lung tumors are not fixed in a single location and move during irradiation due to respiratory motion. Due to limitations in assessing such movements, using a lung phantom can be useful and operational for their fast, easy an...
متن کاملGND-PCA-Based Statistical Modeling of Diaphragm Motion Extracted from 4D MRI
We analyzed a statistical model of diaphragm motion using regular principal component analysis (PCA) and generalized N-dimensional PCA (GND-PCA). First, we generate 4D MRI of respiratory motion from 2D MRI using an intersection profile method. We then extract semiautomatically the diaphragm boundary from the 4D-MRI to get subject-specific diaphragm motion. In order to build a general statistica...
متن کاملComparison of respiratory motion suppression techniques for 4D flow MRI.
PURPOSE The purpose of this work was to assess the impact of respiratory motion and to compare methods for suppression of respiratory motion artifacts in 4D Flow MRI. METHODS A numerical 3D aorta phantom was designed based on an aorta velocity field obtained by computational fluid mechanics. Motion-distorted 4D Flow MRI measurements were simulated and several different motion-suppression tech...
متن کاملT2-Weighted 4D Magnetic Resonance Imaging for Application in Magnetic Resonance–Guided Radiotherapy Treatment Planning
OBJECTIVES The aim of this study was to develop and verify a method to obtain good temporal resolution T2-weighted 4-dimensional (4D-T2w) magnetic resonance imaging (MRI) by using motion information from T1-weighted 4D (4D-T1w) MRI, to support treatment planning in MR-guided radiotherapy. MATERIALS AND METHODS Ten patients with primary non-small cell lung cancer were scanned at 1.5 T axially ...
متن کاملNon rigid respiratory motion correction in whole body PET/MR imaging
INSERM UMR1101, LaTIM, Brest, France Respiratory motion in PET/MR imaging leads to reduced quantitative and qualitative image accuracy. Correction methodologies include the use of respiratory synchronized gated frames which lead to low signal to noise ratio (SNR) given that each frame contains only part of the count available throughout an average PET acquisition. In this work, 4D MRI extracted...