Rebreathing in a T-piece: volunteer and theoretical studies of the Jackson-Rees modification of Ayre's T-piece during spontaneous respiration.

نویسندگان

  • B A Willis
  • J W Pender
  • W W Mapleson
چکیده

The Jackson-Rees modification of Ayre's T-piece was examined experimentally and theoretically to see what effects the theoretical restrictions of Onchi, Hayashi and Ueyama (1957) (1:1 I:E ratio, zero deadspace volume) and the square-wave approximation of Mapleson (1958) may have had on the calculated critical fresh-gas flow rate necessary to prevent rebreathing of exhaled alveolar gases. In the experimental examination six conscious alert volunteers breathed through the system as the fresh-gas flow rate was varied in steps, and their ventilation was recorded at each value. Assuming that under rebreathing conditions a normal arterial PCO2 is maintained by hyperventilation, this experimental situation is identical with one of the two considered theoretically by assuming sine-wave inspiratory and expiratory waveforms, zero longitudinal mixing in deadspace volumes and perfect mixing in the alveoli. Agreement between experimental and theoretical results justifies the assumptions made in the theoretical analysis and the results indicate that a fresh-gas flow rate of about twice the normal ventilation is necessary to eliminate rebreathing completely from the Jackson-Rees modification of Ayre's T-piece. The exact requirement depends on the deadspace/tidal volume (VD/VT) and I:E ratios. The onset of hyperventilation at lower fresh-gas flow rates is gradual and, in spontaneous breathing with VD/VT approximately equal to 40% and I:E ratio = 1:1.2, is only 10-20% at a fresh-gas flow rate of 1.5 times the normal ventilation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rebreathing in a Double T-piece System by Anis Baraka, Bernard Brandstater, Musa Muallem and Cecile Seraphim Summary

A double T-piece paediatric system is described. During spontaneous respiration, the system will perform like a Magill system if the fresh gas flow is delivered via the distal T-piece; the proximal T-piece will provide an outlet. During controlled ventilation the set will perform like a Rees system if the fresh gas flow is delivered via the proximal T-piece; the distal T-piece will provide a co...

متن کامل

The Advantages of a Combined T-piece and Non-rebreathing Valve: a Simple Device.

Ayre's T-piece. The Ayre's T-piece (Ayre, 1937) has a very low resistance, is simple, and almost trouble-free. Intermittent positive pressure respiration (IPPR) can be induced by occluding the exhalation reservoir tube intermittently with one finger. However, the pressure, volume, and riming of lung inflation depends on the flow of gases from the anaesthetic machine and the duration of finger o...

متن کامل

بررسی مقایسه‌ای جداسازی بیماران تحت تهویه مکانیکی از الگوی S.I.M.V به T-piece و S.I.M.V به تنفس خودبخودی و سپس به T-piece در بخش مراقبت‌های ویژه

  Background & Aims : Because for the known complications of prolonged mechanical ventilation, weaning from mechanical ventilation (MV) is very important. We aimed to determine the outcome of two conventional weaning types and comparison of those in patients receiving MV.   Materials & Methods : During an 8 month period we enrolled all patients admitted to intensive care departments who receive...

متن کامل

Artificial ventilation in infants and young children using a new ventilator with the T-piece.

Most ~r,~eSTI~TISTS use some modification of the T-piece technique with endotracheal intubation for infants and small children. The principles have been clearly defined for spontaneous respiration by Mapleson, 1 but there is very little in the literature on the performance of this system with controlled respiration, which is far more commonly indicated, particularly in the infant. The work of H...

متن کامل

A simple T-piece.

THE value of the T-piece principle in reducing the resistance an anaesthetic apparatus offers to respiration is well established. Unfortunately the commonly used Ayre's (1937) T-piece cannot be connected directly to the endotracheal tube. The angled connectors and pieces of rubber tubing which must be interposed markedly increase the resistance of the apparatus to respiration. To overcome this ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 47 12  شماره 

صفحات  -

تاریخ انتشار 1975