Predictive Simulation of Bidirectional Glenn Shunt Using a Hybrid Blood Vessel Model
نویسندگان
چکیده
This paper proposes a method for performing predictive simulation of cardiac surgery. It applies a hybrid approach to model the deformation of blood vessels. The hybrid blood vessel model consists of a reference Cosserat rod and a surface mesh. The reference Cosserat rod models the blood vessel's global bending, stretching, twisting and shearing in a physically correct manner, and the surface mesh models the surface details of the blood vessel. In this way, the deformation of blood vessels can be computed efficiently and accurately. Our predictive simulation system can produce complex surgical results given a small amount of user inputs. It allows the surgeon to easily explore various surgical options and evaluate them. Tests of the system using bidirectional Glenn shunt (BDG) as an application example show that the results produc by the system are similar to real surgical results.
منابع مشابه
Usefulness of central venous oxygen saturation monitoring during bidirectional Glenn shunt.
A PediaSat™ oximetry catheter (PediaSat: Edwards Lifesciences Co., Ltd., Irvine, CA, U. S. A.), which facilitates continuous measurement of central venous oxygen saturation (ScvO2), may be useful for surgery for pediatric congenital heart disease. We used PediaSat during a bidirectional Glenn shunt. The patient was a 13-month-old boy. Under a diagnosis of left single ventricle (pulmonary atresi...
متن کاملDistribution of lung blood on modified bilateral Glenn shunt evaluated by Tc-99m-MAA lung perfusion scintigraphy
The aim of the present study was to determine the distribution of lung blood in a modified bilateral Glenn procedure designed in our institute with lung perfusion scintigraphy. Sixteen consecutive patients who underwent modified bilateral Glenn operation from 2011 to 2014 were enrolled in the study. The control group consisted of 7 patients who underwent bidirectional Glenn shunt. Radionuclide ...
متن کاملSimulation study of Hemodynamic in Bifurcations for Cerebral Arteriovenous Malformation using Electrical Analogy
Background and Objective: Cerebral Arteriovenous Malformation (CAVM) hemodynamic is disease condition, results changes in the flow and pressure level in cerebral blood vessels. Measuring flow and pressure without catheter intervention along the vessel is big challenge due to vessel bifurcations/complex bifurcations in Arteriovenous Malformation patients. The vessel geometry in CAVM patients are...
متن کاملTranscatheter bidirectional Glenn shunt guided by real-time MRI
Methods Ten swine underwent transcatheter bidirectional Glenn procedures under MRI at 1.5T. An MRI antenna-needle was advanced from the superior vena cava (SVC) into the target pulmonary artery (PA) bifurcation using realtime MRI guidance. A caval-pulmonary sheath introduced endografts. Balloon-expansion secured a proximal end-to-end caval anastomosis that also occluded the azygos, and a distal...
متن کاملRapid development of a large systemic-to-pulmonary vein fistula after bidirectional Glenn shunt and successful closure with an Amplatzer duct occluder.
A7-month-old boy presented with significant cyanosis 17 days after bidirectional cavopulmonary shunting (Glenn procedure). He had previously undergone a Norwood operation at 7 days of age for a double-outlet right ventricle with hypoplastic left ventricle, hypoplastic aortic arch, and coarctation. Cardiac catheterization 10 days before the Glenn operation showed a pulmonary venous wedge pressur...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical image computing and computer-assisted intervention : MICCAI ... International Conference on Medical Image Computing and Computer-Assisted Intervention
دوره 12 Pt 2 شماره
صفحات -
تاریخ انتشار 2009