A self‐correcting method for improving the precision of beam blocks
نویسندگان
چکیده
A technique for manufacturing precise custom blocks is described. Using the tracing stylus of the mold making machine, reference markers are cut into the lateral borders of the polystyrene mold after the cavities for the blocks have been made. These markers are aligned with the central ray cross hair of the shadow tray when the blocks are mounted on the tray. The ability of the technique to enhance precision has been verified in laboratory tests by intentionally introducing small imperfections into a mold making machine and checking the positional accuracy of the mounted blocks. The clinical performance has been tested by evaluating 47 check films of blocks for 16 randomly selected patients. The average positional error of individual blocks, projected to the isocenter, was less than one mm. The average time needed to cut the reference markers was 25 seconds. Implementing the technique required only minor modifications of a commercial mold making machine.
منابع مشابه
Evaluation of the physical characteristic of Cerrobend blocks used for radiation therapy
Background: In Radiation Therapy, the sparing of normal tissues can be performed using either multi-leaf collimators or Cerrobend blocks. The current work focuses on the physical characteristics of Cerrobend blocks including attenuation coefficient, effective penumbra width and isodose curves undulation in penumbral regions. Materials and Methods: All measurements were performed using ...
متن کاملTransverse Vibration for Non-uniform Timoshenko Nano-beams
In this paper, Eringen’s nonlocal elasticity and Timoshenko beam theories are implemented to analyze the bending vibration for non-uniform nano-beams. The governing equations and the boundary conditions are derived using Hamilton’s principle. A Generalized Differential Quadrature Method (GDQM) is utilized for solving the governing equations of non-uniform Timoshenko nano-beam for pinned-pinned...
متن کاملThe dosimetry assessment of Varian Linear Accelerators of 6, 15 and 20 MV by Monte Carlo Method
Introduction: Monte Carlo method is often applied in radiation therapy as utilized in all the branches of science. An important requirement for successful radiotherapy is carefully examine the dose distribution specifications and decrease the difference between these features with experience to an acceptable level. In this study, the characteristics of 6, 15 and 20 MeV incident x-rays are prov...
متن کاملImproving Power Density of Piezoelectric Vibration-Based Energy Scavengers
Vibration energy harvesting with piezoelectric materials currently generate up to 300 microwatts per cm2, using it to be mooted as an appropriate method of energy harvesting for powering low-power electronics. One of the important problems in bimorph piezoelectric energy harvesting is the generation of the highest power with the lowest weight. In this paper the effect of the shape and geometry ...
متن کاملOne-point Goppa Codes on Some Genus 3 Curves with Applications in Quantum Error-Correcting Codes
We investigate one-point algebraic geometric codes CL(D, G) associated to maximal curves recently characterized by Tafazolian and Torres given by the affine equation yl = f(x), where f(x) is a separable polynomial of degree r relatively prime to l. We mainly focus on the curve y4 = x3 +x and Picard curves given by the equations y3 = x4-x and y3 = x4 -1. As a result, we obtain exact value of min...
متن کامل