MRI compatible hemodynamic recording system
نویسندگان
چکیده
Background During cardiovascular interventions it is critical to have high-fidelity hemodynamic recordings of physiologic signals for patient safety and procedure guidance. MRI compatible monitoring systems are low-fidelity and not suitable for cardiovascular interventions. We present an MRI compatible hemodynamic recording system designed for MRI guided cardiovascular interventions. It is capable of recording 12-lead ECG, two invasive blood pressures, and pulse oximetry (SpO2), and interfaces to a commercial hemodynamic recording system (Siemens SENSIS).
منابع مشابه
A full-size MRI-compatible keyboard response system.
Two commercially available plastic keyboards were contrasted in the degree to which they interfered with echo planar imaging. One keyboard (GrandTec USA's "Virtually Indestructible Keyboard") caused significantly less temporally variant and invariant signal loss and was integrated into a MRI interface system for recording participants' manual motor responses. The response recording system is sa...
متن کاملA realistic MR compatible aortic phantom to validate hemodynamic parameters from MRI data: aortic coarctation patients comparison using catheterization
Background Recently, 3D printing technologies have emerged as a very innovative technique to produce anatomical replicas. Nevertheless, vessel phantoms built up to now are simplified models, with difficulties to obtain parameters with physiological values. The aim of this work is to show and validate a MR compatible thoracic aorta system, designed to obtain hemodynamic parameters within a range...
متن کاملInteractive real-time mapping and ablation of the pulmonary veins and cavotricuspid isthmus in an ovine model with an externally-irrigated MRI-compatible ablation catheter
Background To date, preclinical studies evaluating MRI-guided ablation have used non-irrigated catheters limited to test lesions in the right heart. Modern complex EP procedures require externally irrigated catheters to produce adequate lesion depth. We present the first feasibility study of an externally-irrigated MRI-compatible ablation catheter, and integrated EP pacing and recording system....
متن کاملAn EEG system with carbon wire electrodes and an anti-polarization circuit for simultaneous EEG-fMRI recording
Background Simultaneous EEG-fMRI (Electroencephalography-functional Magnetic Resonance Imaging) recording offers high temporal resolution electrophysiological recording and high spatial resolution hemodynamic recording from the same experimental runs. Carbon wire electrodes (but not solid electrodes with carbon leads) are suitable for simultaneous EEG-fMRI recording, especially in high field MR...
متن کاملA Frameless Stereotaxic MRI Technique for Macaque Neuroscience Studies
MRI has achieved widespread use for preplanning neuroscience procedures for non-human primate studies. However, orienting imaging studies in stereotaxic space has relied primarily on using a stereotaxic frame or co-registering fiducial markers with the neuroimaging. In this study, we present a simple approach in which the MRI dataset is aligned to the bony landmarks that define the Frankfurt st...
متن کامل