Polarised Multiangular Reflectance Measurements Using the Finnish Geodetic Institute Field Goniospectrometer

نویسندگان

  • Juha Suomalainen
  • Teemu Hakala
  • Jouni Peltoniemi
  • Eetu Puttonen
چکیده

The design, operation, and properties of the Finnish Geodetic Institute Field Goniospectrometer (FIGIFIGO) are presented. FIGIFIGO is a portable instrument for the measurement of surface Bidirectional Reflectance Factor (BRF) for samples with diameters of 10 - 50 cm. A set of polarising optics enable the measurement of linearly polarised BRF over the full solar spectrum (350 - 2,500 nm). FIGIFIGO is designed mainly for field operation using sunlight, but operation in a laboratory environment is also possible. The acquired BRF have an accuracy of 1 - 5% depending on wavelength, sample properties, and measurement conditions. The angles are registered at accuracies better than 2°. During 2004 - 2008, FIGIFIGO has been used in the measurement of over 150 samples, all around northern Europe. The samples concentrate mostly on boreal forest understorey, snow, urban surfaces, and reflectance calibration surfaces.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

SUOMEN GEODEETTISEN LAITOKSEN JULKAISUJA VERÖFFENTLICHUNGEN DES FINNISCHEN GEODÄTISCHEN INSTITUTES PUBLICATIONS OF THE FINNISH GEODETIC INSTITUTE ════════════════════ N:o 146 ═════════════════════ EMPIRICAL STUDIES ON MULTIANGULAR, HYPERSPECTRAL, AND POLARIMETRIC REFLECTANCE OF NATURAL SURFACES

The reflectance factor is a quantity describing the efficiency of a surface to reflect light and affecting the observed brightness of reflected light. It is a complex property that varies with the view and illumination geometries as well as the wavelength and polarization of the light. The reflectance factor response is a peculiar property of each target surface. In optical remote sensing, the ...

متن کامل

Low-cost field goniometer for multiangular reflectance measurements

A low-cost field goniometer was constructed for multiangular reflectance measurements using a spectral radiometer. The goniometer consists of a circular base made of plywood approximately 4 m in diameter. A rotating arch carries a sled with the radiometer, which can be positioned at any angle relative to the test object at the center of the goniometer. Data from the radiometer are downloaded to...

متن کامل

Final Report to THE ANDREW W. MELLON FOUNDATION Validating the Accuracy of the MCSL Imaging Goniospectrometer

This document contains the results from research performed in the summer and fall of 2009 at the Munsell Color Science Laboratory at RIT. The overall goal of the research was to determine a small set of commercially-available materials that can be used to calibrate and verify an imaging goniospectrometer. The specific goals of this project were threefold: 1. Compile a set of materials that can ...

متن کامل

Calibration of the Optech Altm 3100 Laser Scanner Intensity Data Using Brightness Targets

In this paper the calibration of Optech ALTM 3100 laser scanner intensity is reported using airborne experiments and known brightness targets. The Finnish Geodetic Institute has had a permanent photogrammetric test field in Sjökulla Kirkkonummi since 1994. This test field contains permanent and transportable test targets for radiometric calibration, permanent ground control points for small, me...

متن کامل

Land Surface Albedos Computed from BRF Measurements with a Study of Conversion Formulae

Land surface hemispherical albedos of several targets have been resolved using the bidirectional reflectance factor (BRF) library of the Finnish Geodetic Institute (FGI). The library contains BRF data measured by FGI during the years 2003–2009. Surface albedos are calculated using selected BRF datasets from the library. Polynomial interpolation and extrapolation have been used in computations. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2009