Experimental tonography on enucleated human eyes. I. The validity of Grant's tonography formula.
نویسندگان
چکیده
When newer tables for parameters in Grant's formula for tonography are used, one obtains far higher values for the outflow facility than those generally accepted. The aim of this iinvestigation has, therefore, been to test the validity of the tonography formula. The outflow facility determined by constant-rate perfusion in enucleated eyes has been compared with the results of tonography on the same eyes in the steady-state condition. Loss of intraocular fluid during tonography has been measured directly by means of a new technique. Outflow facilities determined according to the two methods show very good agreement. Thus, when the production of aqueous is held at a constant rate, and when there is no change in intraocular blood volume. Grant's tonography formula is found valid, provided absolute values for Po, Pt, and dV are used.
منابع مشابه
Experimental tonography on enucleated human eyes. II. The loss of intraocular fluid caused by tonography.
In clinical work, the loss of intraocular fluid caused by tonography (dV) is usually calculated according to the formula of Grant and Friedenwald. The validity of this formula has been tested by comparing the dV calculated from known factors in the formula with the dV measured directly on enucleated eyes. Our results show a good correlation between the two methods, especially when the rigidity ...
متن کاملEPISCLERAL VENOUS PRESSURE IN TONOGRAPHY * t BY ARTHUR
DURING the 11 years in which the clinical measurement of facility of outflow by means of tonography has been practised, various workers have sought to elucidate and correct the sources of error inherent in this method. One of the assumptions originally made concerning tonography was that the episcleral venous pressure was not disturbed during the measurement. Friedenwald (Grant, 1951) and Becke...
متن کاملComparative aqueous outflow facility measurements by pneumatonography and Schiotz tonography.
Tonography was performed on 36 eyes of 15 normal and 3 primary open angle glaucoma patients using pneumatonography and classical Schiotz tonography. The average values of the coefficient of outflow facility (C) for the whole sample were virtually identical with both methods. However, both intersubject and interobserver variability were significantly higher with penumatonography. Although both m...
متن کاملThe effect of miotics on the intraocular pressure of conscious owl monkeys
1. Nissen, O. I., and Hoppe, R.: The facility of aqueous outflow calculated from the rate of fall in applanation pressure after intravenous acetazolamide in man, Acta Ophthalmol. 52: 390, 1974. 2. Nissen, O. I.: The immediate response in applanation pressure to intravenous acetazolamide in primary glaucomas and glaucoma suspects, Acta Ophthalmol. 53: 537, 1975. 3. Grant, W. M.: Tonographic meth...
متن کاملOn the Consistency of Tonography.
Sixty tonograms of 10 to 40 minutes' duration were analyzed by calculating the outflow facility estimate obtained at each successive minute and during the first 4 minutes with the use of Grant's tonographic equation. The tonographic tracing was found to be a negative exponential function, which, only rarely, is appropriately approximated by a straight line in the first 4 minute segment. It is b...