Development and Validation of Hplc Analytical Methods Used-for Determination of Assay, Content Uniformity and Dissolution of Immediate Release Candesartan Cilexetil 32 Mg Tablets.

نویسندگان

  • Meral Yuce
  • Yilmaz Capan
چکیده

New analytical methods have been developed and validated on high performance liquid chromatography (HPLC) to assess the assay, content uniformity and dissolution of immediate release candesartan cilexetil 32 mg tablets. Method development studies were performed on cyano column. Mobile phase of assay and content uniformity test consisted of mixture of 0.05 M phosphate buffer, pH 4.5 and methanol (40 : 60, v/v) adjusted to pH 4.0 with trifluoroacetic acid, whereas mobile phase of dissolution test consisted of mixture of I mM phosphate buffer and acetonitrile (50 : 50, v/v) adjusted to pH 2.0 with trifluoroacetic acid. Mobile phases were pumped at flow rate of 1.0 mL/min, ultraviolet-visible (UV) detector was operated at 254 nm, injection volume was set at 20 μL, column temperature was held at 25⁰C. Dissolution medium was 0.05 M phosphate buffer, pH 6.5 including 0.70% (w/v) polysorbate 20. Validation studies met acceptance criteria of system suitability, specificity, linearity and range, accuracy, precision, detection limit (LOD), quantitation limit (LOQ) and robustness parameters.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

FORMULATION AND EVALUATION OF CANDESARTAN CILEXETIL IMMEDIATE RELEASE TABLETS Jampani Neeharika*, Bonthu

ABSTRACT Candesartan Cilexetil is an esterified prodrug of Candesartan, a non-peptide angiotensin II type-1(AT1) receptor antagonist used in the treatment of hypertension and congestive heart failure. Candesartan meets the requirement of high potency but it is poorly absorbed when administered orally. Therefore, the prodrug Candesartan Cilexetil is developed. It is soluble in methylene chloride...

متن کامل

Stability Indicating HPLC Method for the Determination of Fulvestrant in Pharmaceutical Formulation in Comparison with Linear Sweep Voltammetric Method

This paper describes two rapid, sensitive and specific methods for the determination of fulvestrant in pharmaceutical preparations by high performance liquid chromatography (HPLC) and linear sweep voltammetry (LSV). HPLC method was used to study the degradation behaviour. Fulvestrant was subjected to degradation under the conditions of hydrolysis (acid and alkali), oxidation (30% H2O2). The lin...

متن کامل

Stability Indicating HPLC Method for the Determination of Fulvestrant in Pharmaceutical Formulation in Comparison with Linear Sweep Voltammetric Method

This paper describes two rapid, sensitive and specific methods for the determination of fulvestrant in pharmaceutical preparations by high performance liquid chromatography (HPLC) and linear sweep voltammetry (LSV). HPLC method was used to study the degradation behaviour. Fulvestrant was subjected to degradation under the conditions of hydrolysis (acid and alkali), oxidation (30% H2O2). The lin...

متن کامل

Potentiometric Method to Determine Montelukast Sodium in its Tablets with In-line Monitoring of its Dissolution Behaviour

Direct drug determination without any pervious treatment steps is the most environmentally friendly method of analysis. Traditional analysis methods usually involve a pre-treatment step before analysis and this consumes time and organic solvents. This work describes direct potentiometric method by using ion selective electrode to determine Montelukast Sodium in its pure drug substance and in ta...

متن کامل

DEVELOPMENT AND VALIDATION OF A RP-HPLC METHOD FOR ESTIMATION OF HYDROCHLOROTHIAZIDE AND CANDESARTAN CILEXETIL IN PHARMACEUTICAL DOSAGE FORM *Ananda Rao Bonthala and T.A.D

A simple, specific and accurate reverse phase high performance liquid chromatographic method was developed for the simultaneous determination of hydrochlorothiazide and candesartan cilexetil in pharmaceutical dosage form. The column used was Zorbax C8 (150×4.6 mm, 3.5μm) in isocratic mode, with mobile phase containing phosphate buffer-methanol (30:70) adjusted to pH 3.0 using ortho phosphoric a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Acta poloniae pharmaceutica

دوره 74 2  شماره 

صفحات  -

تاریخ انتشار 2017