Application of phase consistency to improve time efficiency and image quality in dual echo black-blood carotid angiography.
نویسندگان
چکیده
There is a considerable similarity between proton density-weighted (PDw) and T2-weighted (T2w) images acquired by dual echo fast spin-echo (FSE) sequences. The similarity manifests itself not only in image space as correspondence between intensities of PDw and T2w images, but also in phase space as consistency between phases of PDw and T2w images. Methods for improving the imaging efficiency and image quality of dual echo FSE sequences based on this feature have been developed. The total scan time of dual echo FSE acquisition may be reduced by as much as 25% by incorporating an estimate of the image phase from a fully sampled PDw image when reconstructing partially sampled T2w images. The quality of T2w images acquired using phased array coils may be significantly improved by using the developed noise reduction reconstruction scheme, which is based on the correspondence between the PDw and T2w image intensities and the consistency between the PDw and T2w image phases. Studies of phantom and human subject MRI data were performed to evaluate the effectiveness of the techniques.
منابع مشابه
Unbiased Nonlinear Filtering of Fast Spin Echo MRI Images
Introduction: The design of filtering methods for denoising the magnitude MRI images is traditionally fulfilled assuming that that image noise is zero-mean Gaussian, as Rician properties of magnitude MRI image noise usually complicates a method both algorithmically and computationally [1]. This widely used assumption leads to the biased filtering results, the bias increases as local signal-to-n...
متن کاملPhase-enhancement Technique for a Hybrid-of-opposite-contrast Mr Angiography
Introduction: A Flow-sensitive black-blood (FSBB) technique employing to 3D gradient echo (GRE) with motion-probing-gradient [1], and a MRA technique named Hybrid-of-opposite-contrast (HOP) MR angiography combining TOF and FSBB using dual-echo 3DGRE [2] were proposed. In addition, basic idea for correcting wraparound signal in vessels using phase-corrected real signal in FSBB was also proposed ...
متن کاملProspective-triggered high-pitch spiral versus sequential dual-source CT coronary angiography: comparison of image quality and radiation dose
Background: Prospectively electrocardiography (ECG)-triggered high-pitch spiral coronary computed tomography angiography (CCTA) is a unique scan mode for dual-source CT (DSCT). Our reports aim to compare image quality and radiation dose of CCTA using high-pitch spiral or sequential acquisition mode in patients with low and stable heart rates. Materials and Methods: Patients with low and stable ...
متن کاملTurbo fast three-dimensional carotid artery black-blood MRI by combining three-dimensional MERGE sequence with compressed sensing.
PURPOSE In this study, we sought to investigate the feasibility of turbo fast three-dimensional (3D) black-blood imaging by combining a 3D motion-sensitizing driven equilibrium rapid gradient echo sequence with compressed sensing. METHODS A pseudo-centric phase encoding order was developed for compressed sensing-3D motion-sensitizing driven equilibrium rapid gradient echo to suppress flow sig...
متن کاملHigh resolution 3D diffusion cardiovascular magnetic resonance of carotid vessel wall to detect lipid core without contrast media
BACKGROUND Without the need of contrast media, diffusion-weighted imaging (DWI) has shown great promise for accurate detection of lipid-rich necrotic core (LRNC), a well-known feature of vulnerable plaques. However, limited resolution and poor image quality in vivo with conventional single-shot diffusion-weighted echo planar imaging (SS-DWEPI) has hindered its clinical application. The aim of t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Magnetic resonance imaging
دوره 23 6 شماره
صفحات -
تاریخ انتشار 2005