“Reverse torque of 30 Ncm applied to dental implants as test for osseointegration”—a human observational study
نویسندگان
چکیده
BACKGROUND On bone implantology, stability of a dental implant is an essential clinical tool during osseointegration evaluation, as it is a reflection of the structural and functional connection between the bone and the implant. METHODS The sample was comprised by 17 patients with 40 NanoTec™ and Vellox® implants, placed on the lower jaw, under optimum conditions, after a minimum healing period of 3 months, during stage 2 surgery. RESULTS All 40 implants showed ideal clinical stability after the 30 Ncm reverse torque. There was absence of mobility, absence of radiolucid radiographic images, and symptomatology. CONCLUSIONS The reverse torque is an accepted and non-invasive clinical method for early verification of initial integration, reducing the incidence of possible failure during the first year of prosthetic loading. This is the first study in humans which shows that 30 Ncm is possible, which means a greater safety for prosthetics, since prosthetic parts are turned with up to 35 Ncm.
منابع مشابه
Osseointegration of Zirconia (Y-TZP) Dental Implants: A Histologic, Histomorphometric and Removal Torque Study in the Hip of Sheep
Objectives: The purpose of the present study was to demonstrate the biocompatibility and rigid osseointegration of a zirconia (Y-TZP) dental implant with acid-etched surface. Materials and methods: Eight zirconia (Y-TZP) implants (CeraRoot, Barcelona) were inserted in the hip of an adult sheep. The animal was sacrificed after 2 months. Four implants were used for histology and histomorphometric...
متن کاملDynamic fatigue performance of implant-abutment assemblies with different tightening torque values.
Implant-abutment assemblies are usually subject to long-term cyclic loading. To evaluate the dynamic fatigue performance of implant-abutment assemblies with different tightening torque values, thirty implant-abutment assemblies (Zimmer Dental, Carlsbad, CA, USA) were randomly assigned to three tightening groups (24 Ncm; 30 Ncm; 36 Ncm), each consisted of 10 implants. Five specimens from each gr...
متن کاملManual maximum closing torque in three implant abutment systems
Background and Aims: Diferences whithin shape and size of hand wrenches in diferent systems could affect the torque applied. Therefore, evaluation of wrenches has been emphasized. The aim of the present study was to compare the torque values of the long and short torque wrenches in different implant systems including ITI, Implantium and Nobel Biocare. Materials and Methods: In this experimenta...
متن کاملAdult Stem Cells Properties in Terms of Commitment, Aging and Biological Safety of Grit-Blasted and Acid-Etched Ti Dental Implants Surfaces
Titanium (Ti) is one of the most widely used biomaterials for manufacturing dental implants. The implant surface properties strongly influence osseointegration. The aim of the present study was to in vitro investigate the characteristics of Ti dental implants in terms of mutagenicity, hemocompatibility, biocompatibility, osteoinductivity and biological safety. The Ames test was used to test the...
متن کاملEffect of mechanical cycling on screw torque in external hexagon implants with and without platform switching.
This in vitro study evaluated the effect of mechanical cycling on the torque of retaining screw in external hexagon implants with platform switching (PS), regular platform (RP) and wide platform (WP). A total of 30 specimens were equally divided into 3 groups: PS, PR and WP. Each specimen was prepared with implants: 3.75 x 10 mm for RP group and 5.0x10 mm for PS and WP groups and its respective...
متن کامل