Comparison of ARCHITECT chemiluminiscent microparticle immunoassay for determination of Troponin I in serum with AXYM MEIA technology
نویسنده
چکیده
Introduction: The aim of this study was determination of troponin I at serum using Architect (Abbott) and AxSYM System (Abbott). Troponin is regulatory subunit of the troponin complex associate with actin filament within muscle cells and it is a marker for diagnosis of myocardial damage. Methods: We used Architect STAT chemiluminescent microparticle immunoassay (CMIA) and AxSYM microparticle Enzyme Immunoassay (MEIA), techniques for quantitative determination of cardiac TnI in human serum or plasma. At our study we have proved precision, reproducibility and accuracy from both methods. The investigation included patients (n=119) who have myocardial infarction or ischemic heart damage and were treated at cardiology, emergency, internal medicine and neurology unit in Clinical Center University in Sarajevo. Results: The precision for three controls using Architect STAT TnI asssay technology were 3.6 – 5.2 % and reproducibility was 3.7 to 5.6 %. The AxSYM STAT TnI has precision for three controls 4.3–6.6 % and reproducibility was from 4.8 to 7.8 %. We have got very good correlation between Architect and AxSYM technology r = 0.999 in the investigation of troponin I in serum. Conclusions: We can conclude that chemiluminescent troponin assay I (Architect) showed good analytical performance and gave new possibility at troponin I determination. © 2011 All rights reserved
منابع مشابه
Determination of blood sirolimus concentrations in liver and kidney transplant recipients using the Innofluor® fluorescence polarization immunoassay: Comparison with the microparticle enzyme immunoassay and high-performance liquid chromatography-ultraviolet method
BACKGROUND Although high-performance liquid chromatography (HPLC) is the method of choice for blood sirolimus determination, the microparticle enzyme immunoassay (MEIA) run on the IMx analyser is widely used in therapeutic monitoring of this immunosuppressant agent. The aim of our study was to evaluate the possible determination of sirolimus using the fluorescence polarization immunoassay (FPIA...
متن کاملDetection of antibodies to hepatitis B core antigen using the Abbott ARCHITECT anti-HBc assay: analysis of borderline reactive sera.
Routine use of the automated chemiluminescent microparticle immunoassay Abbott ARCHITECT anti-HBc for diagnosis of hepatitis B is limited in case of borderline reactive sera with low signal close to the cut-off index. In order to determine the significance of anti-HBc detection when borderline reactivity occurs using the ARCHITECT anti-HBc assay, a comparative study was designed. 3540 serum sam...
متن کاملEvaluation of the tacrolimus II microparticle enzyme immunoassay (MEIA II) in liver and renal transplant recipients.
We evaluated the MEIA II with blood samples with added tacrolimus (3.0, 5.0, 11.0, and 22.0 microg/L). The assay had acceptable recoveries (99-103%) and intraday imprecision (<16.0%) across the range of concentrations studied, except for the recoveries at 3.0 microg/L (86.3%) and 5.0 microg/L (80.7%). Comparison of liver (n = 116) and renal (n = 113) patient samples measured by MEIA II against ...
متن کاملComparison of ELISA method versus MEIA method for daily practice in the therapeutic monitoring of tacrolimus.
BACKGROUND For the adequate management of transplant patients on tacrolimus therapy, it is important to obtain optimal blood concentrations. The purpose of this study was to determine the most appropriate method for daily practice of tacrolimus determination in whole blood. We compared enzyme-linked immunosorbent assay (ELISA) with microparticle enzyme immunoassay (MEIA), using European control...
متن کاملComparison of Architect I 2000 for Determination of Cyclosporine with Axsym
BACKGROUND Cyclosporine has been shown effective drug in suppressing acute rejection in recipients of allograft organ transplants. METHODS The cyclosporine concentration of 96 blood samples was determined using CMIA (chemiluminesecent microparticle immnoassay) Architect i 2000 and FPIA (fluorescence polarization immunoassay) AxSYM Abbott diagnostic. All patients have transplantation of kidney...