Blood viscosity in tube flow: dependence on diameter and hematocrit.

نویسندگان

  • A R Pries
  • D Neuhaus
  • P Gaehtgens
چکیده

Since the original publications by Martini et al. (Dtsch. Arch. Klin. Med. 169: 212-222, 1930) and Fahraeus and Lindqvist (Am. J. Physiol. 96: 562-568, 1931), it has been known that the relative apparent viscosity of blood in tube flow depends on tube diameter. Quantitative descriptions of this effect and of the dependence of blood viscosity on hematocrit in the different diameter tubes are required for the development of hydrodynamic models of blood flow through the microcirculation. The present study provides a comprehensive data base for the description of relative apparent blood viscosity as a function of tube diameter and hematocrit. Data available from the literature are compiled, and new experimental data obtained in a capillary viscometer are presented. The combined data base comprises measurements at high shear rates (u > or = 50 s-1) in tubes with diameters ranging from 3.3 to 1,978 microns at hematocrits of up to 0.9. If corrected for differences in suspending medium viscosity and temperature, the data show remarkable agreement. Empirical fitting equations predicting relative apparent blood viscosity from tube diameter and hematocrit are presented. A pronounced change in the hematocrit dependence of relative viscosity is observed in a range of tube diameters in which viscosity is minimal. While a linear hematocrit-viscosity relationship is found in tubes of < or = 6 microns, an overproportional increase of viscosity with hematocrit prevails in tubes of > or = 9 microns. This is interpreted to reflect the hematocrit-dependent transition from single- to multifile arrangement of cells in flow.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Microvascular blood viscosity in vivo and the endothelial surface layer.

The apparent viscosity of blood in glass tubes declines with decreasing diameter (Fåhraeus-Lindqvist effect) and exhibits a distinctive minimum at 6-7 microm. However, flow resistance in vivo in small vessels is substantially higher than predicted by in vitro viscosity data. The presence of a thick endothelial surface layer (ESL) has been proposed as the primary cause for this discrepancy. Here...

متن کامل

Physical basis of the dependence of blood viscosity on tube radius.

HAYNES, ROBERT H. Physical basis of the dependence of blood viscosity on tube radius. Am. J. Physiol. 1g8(6) : I 1g3--1200. 1g6o.-Two theories are applied to measurements of the decrease in apparent viscosity of blood in narrow tubes (FahraeusLindqvist effect). First, the effect may be attributed to the presence of unsheared laminae in the fluid (sigma phenomenon), and it was found that the thi...

متن کامل

Physical basis of the dependence of blood viscosity on tube radius1

HAYNES, ROBERT H. Physical basis of the dependence of blood viscosity on tube radius. Am. J. Physiol. 1g8(6) : I 1g3--1200. 1g6o.-Two theories are applied to measurements of the decrease in apparent viscosity of blood in narrow tubes (FahraeusLindqvist effect). First, the effect may be attributed to the presence of unsheared laminae in the fluid (sigma phenomenon), and it was found that the thi...

متن کامل

Blood flow in microvascular networks. Experiments and simulation.

A theoretical model has been developed to simulate blood flow through large microcirculatory networks. The model takes into account the dependence of apparent viscosity of blood on vessel diameter and hematocrit (the Fahraeus-Lindqvist effect), the reduction of intravascular hematocrit relative to the inflow hematocrit of a vessel (the Fahraeus effect), and the disproportionate distribution of ...

متن کامل

PERFORMANCE MODEL AND ANALYSIS OF BLOOD FLOW IN SMALL VESSELS WITH MAGNETIC EFFECTS

In this paper consider a two-fluid model consisting of a core region of suspension of all the erythrocytes (particles) in plasma (fluid) assumed to be a particle-fluid mixture and a peripheral layer of cell-free plasma (Newtonian fluid), has been proposed to represent blood flow in small diameter tubes with effects of magnetic. The analytical results obtained in the proposed model for effective...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The American journal of physiology

دوره 263 6 Pt 2  شماره 

صفحات  -

تاریخ انتشار 1992