Step-edge calibration of torsional sensitivity for LFM
نویسندگان
چکیده
A novel calibration technique has been developed for lateral force microscopy (LFM). Typically, special preparation of the atomic force microscope (AFM) cantilever or a substrate is required for LFM calibration. The new calibration technique reported in this paper greatly reduces the required preparation processes by simply scanning over a rigid step and measuring the response of the AFM photodiode in the normal and lateral directions. When an AFM tip touches a step while scanning, the tip experiences a reaction force from the step edge, and the amount of torsion can be estimated based on the ratio of the normal and torsional spring constants of an AFM cantilever. Therefore, the torsion can be calibrated using the measured response of the photodiode from the lateral movement of the AFM tip. This new calibration technique has been tested and confirmed by measuring Young’s modulus of a nickel (Ni) nanowire.
منابع مشابه
Lateral force calibration in atomic force microscopy: A new lateral force calibration method and general guidelines for optimization
Proper force calibration is a critical step in atomic and lateral force microscopies (AFM/LFM). The recently published torsional Sader method [C. P. Green et al., Rev. Sci. Instrum. 75, 1988 (2004)] facilitates the calculation of torsional spring constants of rectangular AFM cantilevers by eliminating the need to obtain information or make assumptions regarding the cantilever's material propert...
متن کاملProbing fibronectin–antibody interactions using AFM force spectroscopy and lateral force microscopy
The first experiment showing the effects of specific interaction forces using lateral force microscopy (LFM) was demonstrated for lectin-carbohydrate interactions some years ago. Such measurements are possible under the assumption that specific forces strongly dominate over the non-specific ones. However, obtaining quantitative results requires the complex and tedious calibration of a torsional...
متن کاملTwo Important Issues Relevant to Torsional Response of Asymmetric 8-Story RC BuildingDesigned with Direct Displacement based Design Approach
Direct displacement based design (DDBD) is a conceptual framework that directly design a structure to achieve an expected performance level under specified seismic intensity. In this study, two important issues relevant to torsional response of mass eccentric 8-story RC building designed with DDBD approach are investigated. These issues are including the effects of unbalanced mass distribution ...
متن کاملComparison of different methods to calibrate torsional spring constant and photodetector for atomic force microscopy friction measurements in air and liquid.
A number of atomic force microscopy cantilevers have been exhaustively calibrated by a number of techniques to obtain both normal and frictional force constants to evaluate the relative accuracy of the different methods. These were of either direct or indirect character-the latter relies on cantilever resonant frequencies. The so-called Sader [Rev. Sci. Instrum. 70, 3967 (1999)] and Cleveland [...
متن کاملA New Vertex Similarity Metric for Community Discovery: a Local Flow Model
The hierarchical clustering methods based on vertex similarity have the advantage that global evaluation can be incorporated for community discovery. Vertex similarity metric is the most important part of these methods. However, the existing methods do not perform well for community discovery compared with the state-ofthe-art algorithms. In this paper, we propose a new vertex similarity metric ...
متن کامل