Safety of a Four‐factor Prothrombin Complex Concentrate Versus Plasma for Vitamin K Antagonist Reversal: An Integrated Analysis of Two Phase IIIb Clinical Trials

نویسندگان

  • Truman J. Milling
  • Majed A. Refaai
  • Ravi Sarode
  • Brandon Lewis
  • Antoinette Mangione
  • Billie L. Durn
  • Amy Harman
  • Martin L. Lee
  • Joshua N. Goldstein
چکیده

OBJECTIVES Clinicians often need to rapidly reverse vitamin K antagonists (VKAs) in the setting of major hemorrhage or urgent need for surgery. Little is known about the safety profile of the traditional reversal agent, plasma, or the newly approved agent, four-factor prothrombin complex concentrate (4F-PCC), in a randomized setting. This is an integrated analysis of safety data from two clinical trials that evaluated 4F-PCC versus plasma for the treatment of patients requiring rapid VKA reversal for acute major bleeding or prior to an urgent surgical/invasive procedure. METHODS This descriptive analysis comprised adverse event (AE) data from two phase IIIb, randomized, controlled trials. The bleeding and surgical studies were performed across 36 and 33 sites, respectively, in nine countries, with the integrated analysis comprising 388 patients (4F-PCC, n = 191; plasma, n = 197) aged ≥ 18 years, who required VKA reversal due to major bleeding or prior to an urgent surgical/invasive procedure. Patients received either 4F-PCC, containing nonactivated factors II, VII, IX, and X and proteins C and S (Beriplex/Kcentra, CSL Behring) or plasma, both dosed according to baseline international normalized ratio and body weight. Patients were also to receive vitamin K1. AEs and serious AEs (SAEs) were assessed up to days 10 and 45, respectively. RESULTS The proportion of patients with AEs (4F-PCC, 115/191 [60.2%]; plasma, 124/197 [62.9%]) and SAEs (4F-PCC, 54/191 [28.3%]; plasma, 49/197 [24.9%]) was similar between groups. The proportion of patients with thromboembolic events was also similar between groups (4F-PCC, 14/191 [7.3%]; plasma, 14/197 [7.1%]). There were 13 (6.8%) deaths in the 4F-PCC group and 13 (6.6%) in the plasma group. Fluid overload events occurred in more patients in the plasma group than the 4F-PCC group (25 [12.7%] and 9 [4.7%], respectively). CONCLUSIONS These safety data represent the largest controlled assessment of a 4F-PCC to date. For patients requiring urgent VKA reversal, 4F-PCC had a safety profile similar to that of plasma (AEs, SAEs, thromboembolic events, and deaths), but was associated with fewer fluid overload events.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Efficacy and safety of a 4-factor prothrombin complex concentrate in patients on vitamin K antagonists presenting with major bleeding: a randomized, plasma-controlled, phase IIIb study.

BACKGROUND Patients experiencing major bleeding while taking vitamin K antagonists require rapid vitamin K antagonist reversal. We performed a prospective clinical trial to compare nonactivated 4-factor prothrombin complex concentrate (4F-PCC) with plasma for urgent vitamin K antagonist reversal. METHODS AND RESULTS In this phase IIIb, multicenter, open-label, noninferiority trial, nonsurgica...

متن کامل

Four-Factor Prothrombin Complex Concentrate Reduces Time to Procedure in Vitamin K Antagonist-Treated Patients Experiencing Gastrointestinal Bleeding: A Post Hoc Analysis of Two Randomized Controlled Trials

INTRODUCTION To investigate the impact of a 4-factor prothrombin complex concentrate (4F-PCC [Beriplex®/Kcentra®]) versus plasma on "time to procedure" in patients with acute/severe gastrointestinal bleeding requiring rapid vitamin K antagonist (VKA) reversal prior to invasive procedure. METHODS A post hoc analysis of two phase III trials of 4F-PCC versus plasma in patients with acute/severe ...

متن کامل

Increased risk of volume overload with plasma compared with four-factor prothrombin complex concentrate for urgent vitamin K antagonist reversal.

BACKGROUND Plasma is commonly used for vitamin K antagonist (VKA) reversal, but observational studies suggest that it is associated with transfusion-related adverse reactions (e.g., volume overload). However, this issue has not previously been addressed in a randomized controlled trial (RCT). STUDY DESIGN AND METHODS Factors associated with volume overload were examined using data from two Ph...

متن کامل

Comparison between Prothrombin Complex Concentrate (PCC) and Fresh Frozen Plasma (FFP) for the Urgent Reversal of Warfarin in Patients with Mechanical Heart Valves in a Tertiary Care Cardiac Center

Fresh frozen plasma (FFP) and prothrombin complex concentrate (PCC) reverse oral anticoagulants such as Warfarin. We compared the standard dosage FFP and PCC in terms of efficacy and safety for patients with mechanical heart valves undergoing interventional procedures while receiving Warfarin. Fifty patients were randomized (25 for each group) with mechanical heart valves [international normali...

متن کامل

Comparison between Prothrombin Complex Concentrate (PCC) and Fresh Frozen Plasma (FFP) for the Urgent Reversal of Warfarin in Patients with Mechanical Heart Valves in a Tertiary Care Cardiac Center

Fresh frozen plasma (FFP) and prothrombin complex concentrate (PCC) reverse oral anticoagulants such as Warfarin. We compared the standard dosage FFP and PCC in terms of efficacy and safety for patients with mechanical heart valves undergoing interventional procedures while receiving Warfarin. Fifty patients were randomized (25 for each group) with mechanical heart valves [international normali...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 23  شماره 

صفحات  -

تاریخ انتشار 2016