Reduction of dielectric artifacts within an InSightec ExAblate 4000 head transducer
نویسندگان
چکیده
Background/introduction High intensity focused ultrasound (HIFU) ablation of the brain has been increasingly used as a non-invasive treatment for essential tremor and neuropathic pain. However, artifacts arise in magnetic resonance (MR) images as a result of dielectric properties of the water bath coupler and of the tissues being investigated. As radio frequency (RF) waves enter a dielectric medium, their wavelengths decrease by a factor equal to the square root of the medium’s relative permittivity (Webb 2011). The shortened wavelength can cause a standing wave pattern within the sample, with regions of constructive and destructive interference. This RF inhomogeneity results in dielectric artifacts that appear as shaded regions in the intensity image. Modifying the RF coil can be used to bypass this issue, but is non-trivial. We present a simpler solution by decreasing the permittivity of the water bath, thereby reducing the standing wave effect that creates dielectric artifacts.
منابع مشابه
Bilateral MR imaging-guided high intensity focused ultrasound for the treatment of tremor-dominant Parkinson’s disease: first experience with 9 months follow up
Background/introduction MR imaging-guided high intensity focused ultrasound (MRIgFUS) is a novel, noninvasive technique for the treatment of functional brain disorders through the intact human skull at millimeter precision. The ExAblate 4000 transcranial MRIgFUS system (InSightec, Haifa, Israel) uses a 1024-element phased array transducer, which is attached to the patient’s head via a standard ...
متن کاملEffects of varying duty cycle and pulse width on high-intensity focused ultrasound (HIFU)-induced transcranial thrombolysis
The goal was to test the effects of various combinations of pulse widths (PW) and duty cycles (DC) on high-intensity focused ultrasound (HIFU)-induced sonothrombolysis efficacy using an in vitro flow model. An ExAblate™ 4000 HIFU headsystem (InSightec, Inc., Israel) was used. Artificial blood clots were placed into test tubes inside a human calvarium and exposed to pulsatile flow. Four differen...
متن کاملPre-clinical testing of a phased array ultrasound system for MRI-guided noninvasive surgery of the brain--a primate study.
MRI-guided and monitored focused ultrasound thermal surgery of brain through intact skull was tested in three rhesus monkeys. The aim of this study was to determine the amount of skull heating in an animal model with a head shape similar to that of a human. The ultrasound beam was generated by a 512 channel phased array system (Exablate 3000, InSightec, Haifa, Israel) that was integrated within...
متن کاملMagnetic Resonance guided Focused Ultrasound (MRgFUS) treatment of primary pancreatic and hepatic cancer: preliminary experience in tumor control
Materials and methods After giving their informed consent 5 patients with histologically proven unresectable pancreatic adenocarcinoma and 1 patient with unresectable right lobe HCC (4 males, 2 females; age range 58-72) underwent MRgFUS treatment on a dedicated 3T unit featuring the ExAblate 2100 system (InSightec). The system is composed by a 200-element transducer located within the MR table....
متن کاملMR-guided focused ultrasound for acute stroke: a rabbit model.
R ecent developments in thrombolysis therapy using tissue Plasminogen Activator (tPA) in combination with ultrasound for noninvasive stroke treatment are of great excitement. The first clinical trials have been successfully initiated, demonstrating the potential benefit of transcranial ultrasound in combination with tPA as an effective vessel recanalizing treatment strategy. 6–10 The use of tPA...