Comparative evaluation of the diagnostic accuracy of (99m)Tc-sestamibi gated SPECT using five different sets of image acquisitions at stress and rest phases for the diagnosis of coronary artery disease.

نویسندگان

  • Babak Fallahi
  • Mahdi Haghighatafshar
  • Farinaz Farhoudi
  • Yalda Salehi
  • Farahnaz Aghahosseini
چکیده

On the basis of some new evidences in favor of delayed (99m)Tc methoxy-isobutyl-isonitrile ((99m)Tc-MIBI) redistribution, doubts about the appropriate time of acquisition following radiotracer injection may be raised. The goal of this study was to find the best acquisition time at stress and rest phases to achieve the highest sensitivity and normalcy rate for (99m)Tc-MIBI SPECT. Ninety four patients with moderate pretest probability of coronary artery disease (CAD) according to "Framingham Risk Score" enrolled in the study. Myocardial perfusion imaging (MPI) with SPECT was performed on the basis of two-day protocol with stress- and rest-phase images obtained at 15, 60, 120 and 180 minutes after injection of 666-814 MBq (99m)Tc-MIBI. According to the time of image acquisition at stress/rest phases, five protocols were defined: A, 15/180 min, B, 15/15 min, C, 180/180 min, D, 180/15 min and E, 120/120 min for stress and rest images, respectively. The sensitivity of MPI for the diagnosis of angiographically proven CAD were 77.3%, 50%, 63.6%, 45.5%, 68.2% and normalcy rate were 72.1%, 72.1%, 75.5%, 70.6%, 92.6% in protocol A, B, C, D and E, respectively. A significant association between SSS and Gensini score was detected only with protocol A (p=0.038). The most sensitive and specific two-day protocols for MPI with (99m)Tc-MIBI were protocol A and E, respectively. In addition, the best relationship between scintigraphic score of ischemia and angiographic score of CAD was achieved using protocol A (i.e. early acquisition at stress phase and late acquisition at rest phase).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The role of oral dipyridamole stress gated SPECT in assessing the response of the left ventricle to stress: Re-evaluation of an old method

Introduction: We aimed to assess whether the vasodilator effect of oral dipyridamole on the left ventricular systolic function in patients with suspected CAD is different from that of intravenous (IV) dipyridamole using Tc-99m MIBI myocardial perfusion gated SPECT. Methods: Eighty-nine patients (17 M / 72 W; 61 ± 10 years) were enrolled in this study. The patients underwent a dipyridamole stre...

متن کامل

Nicorandil effect on myocardial perfusion in patients with slow coronary flow phenomenon assessment by gated myocardial perfusion SPECT

Introduction:Patients with the coronary slow flow phenomenon (SCF) frequently experience angina episodes. The purpose of this study was to determine efficacy of nicorandil in myocardial perfusion in patients with SCF. Methods: Twenty patients (50.85 ± 12.96 y) with SCF were studied.  We evaluate coronary slow flow according to protracted thrombolysis in m...

متن کامل

Diagnostic accuracy of rest/stress ECG-gated Rb-82 myocardial perfusion PET: comparison with ECG-gated Tc-99m sestamibi SPECT.

BACKGROUND Although single photon emission computed tomography (SPECT) and positron emission tomography (PET) myocardial perfusion imaging (MPI) have evolved considerably over the last decade, there is no recent comparison of diagnostic performance. This study was designed to assess relative image quality, interpretive confidence, and diagnostic accuracy by use of contemporary technology and pr...

متن کامل

Diagnostic Accuracy of Gated-SPECT Myocardial Perfusion Imaging and Exercise Stress Test for Diagnosis of Coronary Artery Disease

Background and Objective:Accurate diagnosis of CAD using noninvasive procedures is of great importance. The aim of the study is to assess diagnostic accuracy of myocardial perfusion imaging and compare it with exercise stress test in order to decipher a more accurate and cost-effective method for CAD detection. Materials and Methods:Of 430 consecutive patients suspected with CAD, 104 performed...

متن کامل

Gated 99mTc-MIBI myocardial perfusion SPECT in patients with right bundle branch block but without evidence of coronary artery disease

Introduction: We aimed to investigate the effect of right bundle branch block (RBBB) on perfusion and functional parameters in dipyridamole stress/rest Tc99m-MIBI gated myocardial perfusion SPECT (GSPECT) which may be helpful in interpretation of myocardial perfusion imaging. Methods: We studied 73 patients with low pre-test likelihood of coronary artery disease in two groups:  38 patients wit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of nuclear medicine and molecular imaging

دوره 4 1  شماره 

صفحات  -

تاریخ انتشار 2013