Ultimate detectability of volatile organic compounds: how much further can we reduce their ambient air sample volumes for analysis?

نویسندگان

  • Yong-Hyun Kim
  • Ki-Hyun Kim
چکیده

To understand the ultimately lowest detection range of volatile organic compounds (VOCs) in air, application of a high sensitivity analytical system was investigated by coupling thermal desorption (TD) technique with gas chromatography (GC) and time-of-flight (TOF) mass spectrometry (MS). The performance of the TD-GC/TOF MS system was evaluated using liquid standards of 19 target VOCs prepared in the range of 35 pg to 2.79 ng per μL. Studies were carried out using both total ion chromatogram (TIC) and extracted ion chromatogram (EIC) mode. EIC mode was used for calibration to reduce background and to improve signal-to-noise. The detectability of 19 target VOCs, if assessed in terms of method detection limit (MDL, per US EPA definition) and limit of detection (LOD), averaged 5.90 pg and 0.122 pg, respectively, with the mean coefficient of correlation (R(2)) of 0.9975. The minimum quantifiable mass of target analytes, when determined using real air samples by the TD-GC/TOF MS, is highly comparable to the detection limits determined experimentally by standard. In fact, volumes for the actual detection of the major aromatic VOCs like benzene, toluene, and xylene (BTX) in ambient air samples were as low as 1.0 mL in the 0.11-2.25 ppb range. It was thus possible to demonstrate that most target compounds including those in low abundance could be reliably quantified at concentrations down to 0.1 ppb at sample volumes of less than 10 mL. The unique sensitivity of this advanced analytical system can ultimately lead to a shift in field sampling strategy with smaller air sample volumes facilitating faster, simpler air sampling (e.g., use of gas syringes rather than the relative complexity of pumps or bags/canisters), with greatly reduced risk of analyte breakthrough and minimal interference, e.g., from atmospheric humidity. The improved detection limits offered by this system can also enhance accuracy and measurement precision.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pollutants Emissions of Filling Stations and Their Impact on the Air Quality (RESEARCH NOTE)

This study investigated pollutants emissions from filling stations and their impact on the air quality. Gas monitors were employed to identify the different pollutants present in the ambient air of the study areas. The results showed that the most prominent pollutants present in the ambient air are the volatile organic compounds followed by methane, then carbon monoxide. Measurements were taken...

متن کامل

The concentration of volatile organic compounds (VOCs) and related factors in the air in barbershops in Sanandaj in 2016

The aim of this study was to determine the density of benzene and toluene in barbershops of Sanandaj and also to determine effective factors for this pollution. A descriptive, analytical study was conducted to measure the volatile organic compound density and determine the effective factors. In this study, five hair salons and five barber shops were randomly selected from Sanandaj city. The vol...

متن کامل

Recent Advances in Microextraction Methods for Sampling and Analysis of Volatile Organic Compounds in Air: A Review

Human exposures to volatile organic compounds (VOCs) are associated with a wide range of health problems. Due to these adverse effects of VOCs on the human health, determination of trace levels of VOCs is very important for accurate assessment of indoor and outdoor exposure. Solid phase microextraction (SPME), needle trap device (NTD) and hollow fiber- liquid phase microextraction (HF-LPME) are...

متن کامل

Volatile organic compounds in ventilated critical care patients: a systematic evaluation of cofactors

BACKGROUND Expired gas (exhalome) analysis of ventilated critical ill patients can be used for drug monitoring and biomarker diagnostics. However, it remains unclear to what extent volatile organic compounds are present in gases from intensive care ventilators, gas cylinders, central hospital gas supplies, and ambient air. We therefore systematically evaluated background volatiles in inspired g...

متن کامل

Monitoring and Zoning of PM2.5, PM10 and VOCs Concentration in Air of Gorgan City in 2016

Background & Aim: Increasing of air pollution in cities seriously threatens the health of its inhabitants.  PM2.5, PM10 and volatile organic compounds are amongst the air pollutants that their existence in the air in excess concentrations, leads to respiratory and cardiovascular problems, cancer and mortality. Therefore, the concentration of these pollutants in the air of Gorgan city was measur...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical chemistry

دوره 84 19  شماره 

صفحات  -

تاریخ انتشار 2012