Prediction and compensation by an internal model for back forces during finger opening in an overarm throw.
نویسندگان
چکیده
Previous studies have indicated that timing of finger opening in an overarm throw is likely controlled centrally, possibly by means of an internal model of hand trajectory. The present objective was to extend the study of throwing to an examination of the dynamics of finger opening. Throwing a heavy ball and throwing a light ball presumably require different neural commands, because the weight of the ball affects the mechanics of the arm, and particularly, the mechanics of the finger. Yet finger control is critical to the accuracy of an overarm throw. We hypothesized that finger opening in an overarm throw is controlled by a central mechanism that uses an internal model to predict and compensate for movement-dependent back forces on the fingers. To test this idea we determined whether finger motion is affected by back forces, i.e., whether larger back forces cause larger finger extensions. Back forces were varied by having subjects throw, at the same fast speed, tennis-sized balls of different weights (14, 55, and 196 g). Arm- and finger-joint rotations were recorded with the search-coil technique; forces on the middle finger were measured with force transducers. Recordings showed that during ball release, the middle finger experienced larger back forces in throws with heavier balls. Nevertheless, most subjects showed proximal interphalangeal joint extensions that were unchanged or actually smaller with the heavier balls. This was the case for the first throw and for all subsequent throws with a ball of a new weight. This suggests that the finger flexors compensated for the larger back forces by exerting larger torques during finger extension. Supporting this view, at the moment of ball release, all finger joints flexed abruptly due to the now unopposed torques of the finger flexors, and the amplitude of this flexion was proportional to ball weight. We conclude that in overarm throws made with balls of different weights, the CNS predicts the different back forces from the balls and adjusts finger flexor torques accordingly. This is consistent with the view that finger opening in overarm throws is controlled by means of an internal model of the motor apparatus and the external load.
منابع مشابه
Increased variability in finger position occurs throughout overarm throws made by cerebellar and unskilled subjects.
We investigated the ability of cerebellar patients and unskilled subjects to control finger grip position and the amplitude of finger opening during a multijoint overarm throw. This situation is of interest because the appropriate finger control requires predicting the magnitude of back forces from the ball on the finger throughout the throw and generating the appropriate level and rate of chan...
متن کاملControl of finger grip forces in overarm throws made by skilled throwers.
In an overarm throw, as the hand opens and the ball rolls along the fingers, the ball exerts a back force on the fingers. Previous studies suggested that skilled throwers compensate for this back force by producing an appropriate finger flexor torque to oppose the back force, but it was unclear how this is controlled by the CNS. We investigated whether the increase in finger flexor torque is ti...
متن کاملTiming finger opening in overarm throwing based on a spatial representation of hand path.
Previous studies on overarm throwing have suggested that throwing accuracy depends on a precise central timing mechanism. In the present study, we investigated an alternative hypothesis: that central control of finger opening is based on an internal positional representation of handpath. Angular positions of each segment of the middle finger, thumb, and arm were recorded with the search-coil te...
متن کاملFailure of cerebellar patients to time finger opening precisely causes ball high-low inaccuracy in overarm throws.
We investigated the idea that the cerebellum is required for precise timing of fast skilled arm movements by studying one situation where timing precision is required, namely finger opening in overarm throwing. Specifically, we tested the hypothesis that in overarm throws made by cerebellar patients, ball high-low inaccuracy is due to disordered timing of finger opening. Six cerebellar patients...
متن کاملStroboscopic computerized determination of humeral rotation in overarm throwing.
Analysis of the final phase of the overarm handball throw was carried out by a microcomputerized treatment of photographic images taken simultaneously in two grid layouts. Reflective stickers on the joints of the throwing arm (shoulder, elbow, wrist) allowed the coordinates of these three points to be measured against a reference on the wall. Using a mathematical treatment and Euler matrices, t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of neurophysiology
دوره 82 3 شماره
صفحات -
تاریخ انتشار 1999