Plate Thickness and Transducer Distance Dual Inversion with Dry Contact Ultrasonic Lamb Wave Transducers by
نویسندگان
چکیده
in a number of NDE applications. Recent development Ultrasonic Lamb wave techniques are widely used in dry contact Lamb wave transducers enables one to efficiently excite Lamb waves without the aid of liquid couplant. However. i n order to perform thickness measurement i n a plate-like structures. the transducer to accuracy. which places strict mechanical requirements transducer distance has to be tixed and known to a good during actual implementation. In this paper. we propose a novel technique that utilizes pectrum analysis on the receiver signal and invert for both the plate thickness and transducer to transducer distance. A pair of pin transducers are used to excite and detect the A, mode Lamb wave in a plate and the receiver waveform is captured for a windowed F R . The signal phase changes with both the plate thickness and the transmitter to receiver distance. but with different sensitivity coefficients. Therefore. with proper calibration. we are able to use an optimization algorithm to perform simultaneous thickness and distance inversion. With the relaxed requirement for known transducer to transducer distance. this technique extends the advantages of the dry contact transducers with added implementation flexibility.
منابع مشابه
Lamb Wave Tomography and Its Application in Pipe Erosion/corrosion Monitoring
number of NDE applications. To excite Lamb waves, Ultrasonic Lamb wave techniques are widely used in a mode conversion of bulk waves or photo acoustic excitation are often used. Both of these approaches suffer from the need for liquid couplant or ablation of materials to reach good signal to noise ratio. In this paper, we propose a novel technique that utilizes point source excitation and detec...
متن کاملInductive coupling for wireless Lamb wave and longitudinal wave transducers
Piezoelectric transducers have been widely used for the generation and detection of ultrasonic waves for structural health monitoring. Recently, we proposed the use of inductive coupling in order to implement wireless coupling to a Lamb wave transducer. In that transducer the ultrasonic waves were generated by a piezoelectric wafer attached to the surface of a plate. These transducers are effec...
متن کاملMulti-Mode and Multi-Frequency Differential Lamb Wave Imaging with in situ Sparse Transducer Arrays
Application of ultrasonic methods to structural health monitoring requires a compromise between coverage and complexity, making it desirable to use as few transducers as possible to cover the largest area. Such a consideration leads to the use of very sparse arrays where transducers are spatially distributed over a large area and are permanently attached to the structure. For plate-like geometr...
متن کاملDefects Evaluation in Lamb Wave Testing of Thin Plates
In the present study, dispersion and displacement curves of ultrasonic lamb wave, propagated in Aluminum thin plates, were drawn. Two ultrasonic lamb wave techniques, pulse-echo (a1 mode as emitter) and emission (s1 mode as emitter), were used for interpretation of notch defects with depths of 10%, 30% and 60% of plate thickness. Thickness of plate was 2 mm and the nominal centre frequency of t...
متن کاملHertzian contact transducers for nondestructive evaluation
Hertzian, dry, pointlike contacts are used to couple ultrasonic energy efficiently to plate wave modes in anisotropic solid plates. A new transducer configuration using a piezoelectric PZT-5H transducer and a quartz buffer rod is realized for this purpose. In particular, the lowest order antisymmetric Lamb wave (A0) mode is excited and detected in anisotropic plates at a frequency of 200 kHz an...