Infrared Thermography and Ultrasonography to Indirectly Monitor the Influence of Liner Type and Overmilking on Teat Tissue Recovery
نویسندگان
چکیده
Eight Danish Holstein cows were milked with a 1-mm thick specially designed soft liner on their right rear teat and a standard liner mounted under extra high tension on their left rear teat. Four of the animals were overmilked for 5 min. Rear teats were subjected to ultrasound examination on the first day and to infrared thermography on the second day. Teats were submersed in ethanol 20 min post-milking on the second day. Ultrasonography measurements showed that teat canal length increased by 30-41% during milking. Twenty minutes after milking, teats milked with modified standard liners still had elongated teat canals while teats milked with the soft liner were normalized. Overmilking tended to increase teat wall thickness. Approximately 80% of variability in teat canal length, from before teat preparation to after milking, could be explained by changes during teat preparation. Thermography indicated a general drop in teat temperature during teat preparation. Teat temperature increased during milking and continued to increase until the ethanol challenge induced a significant drop. Temperatures approached pre-challenge rather than pre-milking temperatures within 10 minutes after challenge. Teat temperatures were dependent on type of liner. Mid-teat temperatures post-challenge relative to pre-teat preparation were dependent on overmilking. Thermography and ultrasound were considered useful methods to indirectly and non invasively evaluate teat tissue integrity.
منابع مشابه
Effect of liner design, pulsator setting, and vacuum level on bovine teat tissue changes and milking characteristics as measured by ultrasonography
: Friesian-type dairy cows were milked with different machine settings to determine the effect of these settings on teat tissue reaction and on milking characteristics. Three teat-cup liner designs were used with varying upper barrel dimensions (wide-bore WB = 31.6 mm; narrow-bore NB = 21.0 mm; narrow-bore NB1 = 25.0 mm). These liners were tested with alternate and simultaneous pulsation patter...
متن کاملFollowing a patient with breast cysts using thermal imaging: case report
Background: Breast cancer is a common malignancy in which early breast cancer detection by the help of imaging can improve the treatment outcome. Thermography utilizes infrared beams which are fast, non-invasive, and non-contact and the output created images by this technique are flexible and useful to monitor the temperature of the human body. Case presentation: Our patient is a 25-year-old w...
متن کاملExperimental Detection of Composite Delamination Damage based on Ultrasonic Infrared Thermography
An experimental setup is designed to detect composite delamination damage based on ultrasonic infrared thermography. The ultrasonic infrared thermography system is composed by ultrasonic excitation system, infrared thermal imager and data acquisition system and two damaged composite plate specimens are produced in the experiment. The image processing methods including thresholding, filters, edg...
متن کاملOvermilking and Teat Condition
Overmilking is a matter of concern because it may affect teat condition and udder health. The historic background for overmilking is mainly based on the assumption that all milk should be removed from the udder in order to maximise the milk yield. However, breeding for high milk yields has provided cows with a high alveolar capacity, large cistern capacity, and a higher proportion of cisternal ...
متن کاملThe Use of a Pressure-Indicating Film to Determine the Effect of Liner Type on the Measured Teat Load Caused by a Collapsing Liner
During milking the teat cup liner is the interface between the teat of a dairy cow and the milking system, so it should be very well adapted to the teat. Therefore, the aim of the present study was to determine the effect of liner type on the directly measuring teat load caused by a collapsing liner with a pressure-indicating film. The Extreme Low pressure-indicating film was used to detect the...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Acta Veterinaria Scandinavica
دوره 46 شماره
صفحات -
تاریخ انتشار 2005