Evaluation of dosimetric variance in whole breast forward-planned intensity-modulated radiotherapy based on 4DCT and 3DCT

نویسندگان

  • Wei Wang
  • Jian Bin Li
  • Hong Guang Hu
  • Tao Sun
  • Min Xu
  • Ting Yong Fan
  • Qian Shao
چکیده

This study was performed to explore and compare the dosimetric variance caused by respiratory movement in the breast during forward-planned IMRT after breast-conserving surgery. A total of 17 enrolled patients underwent the 3DCT simulation scans followed by 4DCT simulation scans during free breathing. The treatment planning constructed using the 3DCT images was copied and applied to the end expiration (EE) and end inspiration (EI) scans and the dose distributions were calculated separately. CTV volume variance amplitude was very small (11.93 ± 28.64 cm(3)), and the percentage change of CTV volumes receiving 50 Gy and 55 Gy between different scans were all less than 0.8%. There was no statistically significant difference between EI and EE scans (Z =-0.26, P = 0.795). However, significant differences were found when comparing the Dmean at 3DCT planning with the EI and EE planning (P = 0.010 and 0.019, respectively). The homogeneity index at EI, EE and 3D plannings were 0.139, 0.141 and 0.127, respectively, and significant differences existed between 3D and EI, and between 3D and EE (P = 0.001 and 0.006, respectively). The conformal index (CI) increased significantly in 3D treatment planning (0.74 ± 0.07) compared with the EI and EE phase plannings (P = 0.005 and 0.005, respectively). The V30, V40, V50 and Dmean of the ipsilateral lung for EE phase planning were significantly lower than for EI (P = 0.001-0.042). There were no significant differences in all the DVH parameters for the heart among these plannings (P = 0.128-0.866). The breast deformation during respiration can be disregarded in whole breast IMRT. 3D treatment planning is sufficient for whole breast forward-planned IMRT on the basis of our DVH analysis, but 4D treatment planning, breath-hold, or respiratory gate may ensure precise delivery of radiation dose.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of dosimetric radiotherapy of whole left- breast cancer using conventional tangential wedge-based techniques (CTT) and three intensity modulation techniques (IMRT)

Introduction: Whole breast radiotherapy after breast-conserving surgery decrease the risk of local recurrence. this study investigates the dosimetric aspects of intensity modulated radiotherapy (IMRT) compared to conventional tangential wedge-based beams techniques (CTT) of the whole breast in early stages breast cancer patients.   Materials and Methods: Co...

متن کامل

Dosimetric comparison of 3-dimensional conformal and intensity-modulated radiotherapy techniques for whole breast irradiation in the prone and supine positions

Background: The aim of this study was to compare the differences of the dosimetric parameters between three-dimensional conformal radiotherapy (3D-CRT) and simultaneous-integrated boost intensity-modulated radiotherapy (SIB-IMRT) techniques in the prone and supine positions for breast irradiation. Materials and Methods: Ten patients underwent a computed tomography simulation in both the prone a...

متن کامل

A comparison of dosimetric variance for external-beam partial breast irradiation using three-dimensional and four-dimensional computed tomography

Objective: To investigate the potential dosimetric benefits of four-dimensional computed tomography (4DCT) compared to three-dimensional CT (3DCT) in the planning of radiotherapy for external-beam partial breast irradiation (EB-PBI). Methods: Three-DCT and 4DCT scan sets were acquired for 20 patients who underwent EB-PBI. For each patient a conventional 3D conformal plan (3D-CRT) was generated ...

متن کامل

Analysis of Predictive Factors for Lung Injury after Forward-Planned Intensity-Modulated Radiotherapy in Whole Breast Irradiation

PURPOSE This study was performed to assess frequency, timings of occurrence, and predictors of radiologic lung damage (RLD) after forward-planned intensity-modulated radiotherapy (FIMRT) for whole breast irradiation. METHODS We retrospectively reviewed medical records of 157 breast cancer patients and each of their serial chest computed tomography (CT) taken 4, 10, 16, and 22 months after com...

متن کامل

Evaluation of treatment planning system monitor unit calculations for three intensity modulated radiotherapy delivery techniques

Background: We have validated the monitor unit calculations from a commercially available treatment planning system (TPS) for three intensity modulated radiotherapy (IMRT) planning techniques for tangential breast irradiation by using ionization chamber measurements. Materials and Methods: Treatment plans were generated for forty-two breast patients by a forward planned field in field ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 54  شماره 

صفحات  -

تاریخ انتشار 2013