Semiautomatic carotid lumen segmentation for quantification of lumen geometry in multispectral MRI
نویسندگان
چکیده
Quantitative information about the geometry of the carotid artery bifurcation is relevant for investigating the onset and progression of atherosclerotic disease. This paper proposes an automatic approach for quantifying the carotid bifurcation angle, carotid area ratio, carotid bulb size and the vessel tortuosity from multispectral MRI. First, the internal and external carotid centerlines are determined by finding a minimum cost path between user-defined seed points where the local costs are based on medialness and intensity. The minimum cost path algorithm is iteratively applied after curved multi-planar reformatting to refine the centerline. Second, the carotid lumen is segmented using a topology preserving geodesic active contour which is initialized by the extracted centerlines and steered by the MR intensities. Third, the bifurcation angle and vessel tortuosity are automatically extracted from the segmented lumen. The methods for centerline tracking and lumen segmentation are evaluated by comparing their accuracy to the inter- and intra-observer variability on 48 datasets (96 carotid arteries) acquired as part of a longitudinal population study. The evaluation reveals that 94 of 96 carotid arteries are segmented successfully. The distance between the tracked centerlines and the reference standard (0.33 mm) is similar to the inter-observer variation (0.32 mm). The lumen segmentation accuracy (average DSC=0.89, average mean absolute surface distance=0.31 mm) is close to the inter-observer variation (average dice=0.92, average mean surface distance=0.23 mm). The correlation coefficient of manually and automaticly derived bifurcation angle, carotid proximal area ratio, carotid proximal bulb size and vessel totuosity quantifications are close to the correlation of these measures between observers. This demonstrates that the automated method can be used for replacing manual centerline annotation and manual contour drawing for lumen segmentation in MRIs data prior to quantifying the carotid bifurcation geometry.
منابع مشابه
Lumen segmentation and stenosis quantification of atherosclerotic carotid arteries in CTA utilizing a centerline intensity prior.
PURPOSE The degree of stenosis is an important biomarker in assessing the severity of cardiovascular disease. The purpose of our work is to develop and evaluate a semiautomatic method for carotid lumen segmentation and subsequent carotid artery stenosis quantification in CTA images. METHODS The authors present a semiautomatic stenosis detection and quantification method following lumen segmen...
متن کاملA Semi-automatic Method for Segmentation of the Carotid Bifurcation and Bifurcation Angle Quantification on Black Blood MRA
Quantitative information about the geometry of the carotid artery bifurcation may help in predicting the development of atherosclerosis. A geodesic active contours based segmentation method combining both gradient and intensity information was developed for semi-automatic, accurate and robust quantification of the carotid bifurcation angle in Black Blood MRA data. The segmentation method was ev...
متن کاملManual versus Automated Carotid Artery Plaque Component Segmentation in High and Lower Quality 3.0 Tesla MRI Scans
PURPOSE To study the interscan reproducibility of manual versus automated segmentation of carotid artery plaque components, and the agreement between both methods, in high and lower quality MRI scans. METHODS 24 patients with 30-70% carotid artery stenosis were planned for 3T carotid MRI, followed by a rescan within 1 month. A multicontrast protocol (T1w,T2w, PDw and TOF sequences) was used. ...
متن کاملBayes Clustering and Structural Support Vector Machines for Segmentation of Carotid Artery Plaques in Multicontrast MRI
Accurate segmentation of carotid artery plaque in MR images is not only a key part but also an essential step for in vivo plaque analysis. Due to the indistinct MR images, it is very difficult to implement the automatic segmentation. Two kinds of classification models, that is, Bayes clustering and SSVM, are introduced in this paper to segment the internal lumen wall of carotid artery. The comp...
متن کاملCarotid bifurcation geometry is an independent predictor of early wall thickening at the carotid bulb.
BACKGROUND AND PURPOSE Lumen geometry has long been suspected as a risk factor for atherosclerosis by virtue of its influence on blood flow disturbances. Confirmation of this geometric risk hypothesis has, however, proved challenging owing to possible effects of wall thickening on geometry and unproven links between candidate geometric variables and disturbed flow. The purpose of this study was...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical image analysis
دوره 16 6 شماره
صفحات -
تاریخ انتشار 2012