Clinical experience of the importance of daily portal imaging for head and neck IMRT treatments
نویسندگان
چکیده
The purpose of this study was to evaluate patient setup in head and neck IMRT using daily portal imaging. At our institution, orthogonal digital portal images are taken daily to check patient positioning prior to head and neck IMRT treatment. Isocenter misalignments are corrected using a couch shift (3mm action level). Therapists also compare the DRRs and portal images looking at points more distant from the isocenter, particular in the supraclavicular region, and re-position the patient's shoulders in the mask if considered necessary. The daily isocenter shifts (C2 region) and frequency of patient repositioning were investigated by review of record-and-verify records for 15 patients. The magnitude of the shoulder repositioning was evaluated for 10 of these patients by comparing portal images and plan DRRs for a point 8 cm inferior of isocenter (T2-T4). For all patients, pretreatment isocenter discrepancies 3mm or smaller were recorded for a median of 92.5% of fractions (range: 71.4 -100%). Patients were repositioned in the immobilization mask before treatment for a median of 14% of fractions (3-34%). Thirty percent of these were for shoulder shifts of 1cm or larger. Twenty percent of patients needed shoulder shifts of 1cm or more for more than 7/35 fractions, meaning that without setup based on daily imaging, parts of the CTV would have received less than 95% of the prescribed dose. In conclusion, with our current immobilization, isocenter positioning accuracy is excellent, while correct shoulder position is more variable, particularly for a small subset of patients. Frequent imaging of head and neck IMRT patients is essential to accurate delivery of therapy, with shoulder position an important factor.
منابع مشابه
Utilization of Electronic Portal Imaging Device (EPID) For Setup Verification and Determination of Setup Margin in Head and Neck Radiation Therapy
Introduction: Radiation therapy involves a multistep procedure; therefore, the error in patient set up is an inherent part of the treatment. Main purpose of this study was to determine the clinical target volume (CTV) to planning target volume (PTV) in head and neck cancer patients. Material and Methods: A total of 15 patients who had daily p...
متن کاملDose Distribution Analysis of Rapid Arc and Intensity Modulated Radiotherapy Plan in Head and Neck Cancer
Introduction: Globally, intensity-modulated radiation therapy (IMRT) is considered as highly precise and accurate method of radiotherapy planning. This technique amplifies spatial dose distribution conformity by modulating the intensity of radiation beams in each sub-volume. Additionally, it can reduces the dose to surrounding critical organs and deliver the planned dose to targets with the nom...
متن کاملAssessment of a 2D EPID-based Dosimetry Algorithm for Pre-treatment and In-vivo Midplane Dose Verification
Introduction: The use of electronic portal imaging devices (EPIDs) is a method for the dosimetric verification of radiotherapy plans both pretreatment and in-vivo. The aim of this study was to test a 2D EPID-based dosimetry algorithm for dose verification of some plans inside a homogenous and anthropomorphic phantom and in-vivo, as well. Materials and Methods: </strong...
متن کاملThe effect of high energy photon beam in dose- volume parameters and integral dose of normal structures in Head and neck IMRT
Introduction: The aim of this study is to investigate the effect of partially used high photon energies on dosimetric parameters and integral doses of nasopharynx IMRT plans. Materials and Methods: Two 7 coplanar IMRT plan were created for eleven patients (6 MV only IMRT plan in both phase1 and phase2 and 6 MV phase1-mixed energies (6 MV and 15 MV) phase2...
متن کاملNon-uniformity of Clinical Head, Head and Neck, and Body Coils in Magnetic Resonance Imaging (MRI)
Introduction Signal intensity uniformity in a magnetic resonance (MR) image indicates how well the MR imaging (MRI) system represents an object. One of the major sources of image non-uniformity in high-field MRI scanners is inhomogeneity of radio-frequency coil. The aim of this study was to investigate non-uniformity in head, head and neck, and body coils and compare the obtained results to det...