Development of a new introduction technique for the pulsatile catheter pump.

نویسندگان

  • D Mihaylov
  • C Kik
  • J Elstrodt
  • G J Verkerke
  • P K Blanksma
  • G Rakhorst
چکیده

The pulsatile catheter (PUCA) pump is an intraventricular blood pump that can be introduced into the left ventricular cavity through a superficial artery (transarterially) or directly through the thoracic aorta during open chest conditions. When positioned, the pump aspirates blood from the left ventricle and transports it into the ascending aorta. A pneumatic driving system allows the blood to be ejected in early diastole of every second or third heart beat. The main goal of this study was to develop an easy, fast, safe surgical introduction technique. Four different means of catheter introduction were tested in 20 acute open chest experiments with calves: introduction without any guidance at all, introduction by x-ray guidance only, introduction using a guide wire plus x-ray guidance, and introduction using a guiding pressure catheter. Introducing the PUCA pump catheter into the left ventricular cavity using a pigtail guiding pressure catheter proved to be easy. The large bore pump catheter followed the guiding catheter and passed the aortic valve well. The position of the PUCA pump could be monitored from the pressure patterns derived from the guiding catheter.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effects of pulsatile flushing on phlebitis and peripheral intravenous catheters patency

Background and Aim: Thrombophlebitis is considered as a major cause of peripheral intravenous catheters (PICs) failure. The flushing technique in the laboratory has been effective in clearing the catheter duct, but its effectiveness in the clinical setting is unknown, therefore, the aim of this study was to determine the effect of pulsatile flushing on phlebitis, type, and duration of PICs pate...

متن کامل

In vivo and in vitro experience with the PUCA-II, a single-valved pulsatile catheter-pump.

The Pulsatile Catheter (PUCA) pump is a trans-arterial pulsatile ventricular assist device that can be used for short-term left ventricular support. The separate inflow and outflow valves in the first version of the device (PUCA-I) were replaced by a single inflow/outflow valve in the latest PUCA pump version (PUCA-II). The new combined valve was tested during in vitro (mock circulation) and in...

متن کامل

The PUCA pump: a left ventricular assist device.

Left ventricular assist devices (LVADs) that are being used clinically still have specific drawbacks. Therefore, a new concept for mechanical circulatory support was developed, the pulsatile catheter (PUCA) pump. It consists of an extracorporeally placed, pneumatically driven membrane pump that is connected to a valved catheter. The catheter is introduced into an easily accessible artery and po...

متن کامل

Use of Foley Catheter Instead of Digital Rectal Examination for Detection of Gastrointestinal Bleeding in Infants and Children

A digital rectal examination is a highly important procedure carried out on infants and children during visits to the gastroenterology clinic, but is often accompanied with physiologic and psychologic trauma in patients, along with being diagnostically inaccurate in the results obtained from it. In order to avoid causing discomfort to the patients, and to improve the accuracy of the results obt...

متن کامل

PULSATILE MOTION OF BLOOD IN A CIRCULAR TUBE OF VARYING CROSS-SECTION WITH SLIP FLOW

Pulsatile motion of blood in a circular tube of varying cross-section has been developed by considering slip flow at the tube wall and the blood to be a non- Newtonian biviscous incompressible fluid. The tube wall is supposed to be permeable and the fluid exchange across the wall is accounted for by prescribing the normal velocity of the fluid at the tube wall. The tangential velocity of the fl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Artificial organs

دوره 21 5  شماره 

صفحات  -

تاریخ انتشار 1997