Prospective head motion correction using FID-guided on-demand image navigators.

نویسندگان

  • Maryna Waszak
  • Pavel Falkovskiy
  • Tom Hilbert
  • Guillaume Bonnier
  • Bénédicte Maréchal
  • Reto Meuli
  • Rolf Gruetter
  • Tobias Kober
  • Gunnar Krueger
چکیده

PURPOSE We suggest a motion correction concept that employs free-induction-decay (FID) navigator signals to continuously monitor motion and to guide the acquisition of image navigators for prospective motion correction following motion detection. METHODS Motion causes out-of-range signal changes in FID time series that, and in this approach, initiate the acquisition of an image navigator. Co-registration of the image navigator to a reference provides rigid-body-motion parameters to facilitate prospective motion correction. Both FID and image navigator are integrated into a prototype magnetization-prepared rapid gradient-echo (MPRAGE) sequence. The performance of the method is investigated using image quality metrics and the consistency of brain volume measurements. RESULTS Ten healthy subjects were scanned (a) while performing head movements (nodding, shaking, and moving in z-direction) and (b) to assess the co-registration performance. Mean absolute errors of 0.27 ± 0.38 mm and 0.19 ± 0.24° for translation and rotation parameters were measured. Image quality was qualitatively improved after correction. Significant improvements were observed in automated image quality measures and for most quantitative brain volume computations after correction. CONCLUSION The presented method provides high sensitivity to detect head motion while minimizing the time invested in acquiring navigator images. Limits of this implementation arise from temporal resolution to detect motion, false-positive alarms, and registration accuracy. Magn Reson Med 78:193-203, 2017. © 2016 International Society for Magnetic Resonance in Medicine.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prospective motion correction with FID-triggered image navigators

shaking; (b) Changes in volumetric measurements and image quality due to motion correction). The p-value is shown as calculated with the Wilcoxon rank-sum test when comparing the volumes with and without correction. 1417 Prospective motion correction with FID-triggered image navigators Maryna Babayeva, Pavel Falkovskiy, Tom Hilbert, Guillaume Bonnier, Bénédicte Maréchal, Reto Meuli, Jean-Philip...

متن کامل

Hybrid Prospective & Retrospective Head Motion Correction System to Mitigate Cross-Calibration Errors

INTRODUCTION – Correction of head motion artifacts is essential for clinically acceptable image quality. This is especially important for long scans, such as DTI, fMRI, and high-resolution structural scans. Prospective motion-correction using stereovision systems [1,2] have been suggested to perform real-time head motion-correction without necessitating the acquisition of additional MR-based na...

متن کامل

Prospective head motion correction in 3D FLASH using EPI-based volumetric navigators (vNavs)

Prospective head motion correction in 3D FLASH using EPI-based volumetric navigators (vNavs) M. Dylan Tisdall, Himanshu Bhat, Keith Heberlein, and André J. W. van der Kouwe A. A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, United States, Radiology, Harvard Medical School, Boston, Massachusetts, United States, Siemens Medical Solutions USA ...

متن کامل

Real-time Motion Detection for Structural Brain Imaging Using Multi-Coil FID Navigators

Fig. 2 Uncorrected (black) and corrected (blue) navigator signal of an MP-RAGE measurement. Head position was changed during the period marked violet. The green bars show motion threshold at that moment, red points mark motion-corrupted TRs, which are rescanned at the end (pink bar). Cyan shows the online regression time course. Real-time Motion Detection for Structural Brain Imaging Using Mult...

متن کامل

Motion correction in simultaneous PET/MR brain imaging using sparsely sampled MR navigators: a clinically feasible tool

BACKGROUND We present a study performing motion correction (MC) of PET using MR navigators sampled between other protocolled MR sequences during simultaneous PET/MR brain scanning with the purpose of evaluating its clinical feasibility and the potential improvement of image quality. FINDINGS Twenty-nine human subjects had a 30-min [(11)C]-PiB PET scan with simultaneous MR including 3D navigat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 78 1  شماره 

صفحات  -

تاریخ انتشار 2017