ESR Spatiotemporal Measurement Using the Rapid Field Scan L-Band ESR-CT System for Determination of Rate Constants of Nitroxide Radical Reduction
نویسندگان
چکیده
The rate constants of nitroxide reduction by ascorbate ion were determined from a time-series measurement of ESR images, that is, ESR spatiotemporal images, which were measured with a rapid field scan L-band ESR-CT system. Two test tubes containing the phosphate buffer solutions of 3-carbamoyl-2,2,5,5-tetramethylpyrrolidin-l-yloxy (C-PROXYL) and ascorbate ion with different concentrations were placed together in the loop-gap resonator and a time-series measurement of 2-dimensional ESR images were obtained. The first-order rate constants for each reduction were determined from the time course of the total gray scale at each test tube region. These rate constants agreed with those measured individually from L-band or X-band ESR spectra.
منابع مشابه
Relationship between Severity of Primary Lung Involvement with Erythrocyte Sedimentation Rate and Lactate Dehydrogenase in Patients with COVID-19 in Yazd
Background and Objective: Measurement of inflammatory markers and lactate dehydrogenase (LDH) may contribute to the evaluation of lung involvement severity. This study aimed to evaluate relationship between severity of primary lung involvement with highest level of erythrocyte sedimentation rate (ESR) and LDH in patients with COVID-19. Materials and Methods: This descriptive-analytical study w...
متن کاملAberration of Erythrocyte Sedimentation Rate by Zinc Nanoparticles
Dear Editor, erythrocyte sedimentation rate (ESR) is a useful basic clinical pathology laboratory investigation. It can be helpful in diagnosis and follow-up of several diseases. At present, a new automated method with proven reliability is available for ESR test (1). Here, the authors report on observation on a laboratory experiment to test the effect of zinc nanoparticles on ESR results. The...
متن کاملElectron spin resonance spectroscopy studies on reduction process of nitroxyl radicals used in molecular imaging
Electron spin resonance (ESR) spectroscopy studies on the reduction process of nitroxyl radicals were carried out for 1mM concentration of 14 N-labeled nitroxyl radicals in 1 mM concentration of ascorbic acid as a function of time. The half life time and decay rate were estimated for 1mM concentration of 14 N labeled nitroxyl radicals in 1 mM concentration of ascorbic acid. From the results, th...
متن کاملMeasurement of the Adsorbed Radiation Dose to Eyelens During CT Scan and Radiotherapy of Nasopharynx Cancer
Introduction: The study of the cause of death during the last few decades has shown that death due to infectious diseases has been declining and has been rising due to noninvasive diseases, especially cancers and accidents. Cancer is considered as one of the fatal diseases, and every year, more than 10.9 million people worldwide are diagnosed with the disease. Mater...
متن کاملEffects of High Doses of X-Ray on Hematological Parameters and Morphology of Red Blood Cells in Human Blood
Introduction: The aim of the current study was to investigate the effects of X-ray radiation on some hematological parameters, morphology of red blood cells (RBC) and erythrocyte sedimentation rate (ESR) analysis of human blood using computed tomography (CT) scanner. Material and Methods: For the purpose of the study, 5 ml of wholeblood was drawn from vein puncture of 28 healthy people and div...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2006