In-process phase growth measurement technique in the fabrication of monolithic porous layer open tubular (monoPLOT) columns using capacitively coupled contactless conductivity.
نویسندگان
چکیده
A technique for the in-process measurement of polymer stationary phase growth inside fused silica capillaries during the fabrication of monolithic porous layer open tubular (monoPLOT) columns is presented. In this work, capacitively coupled contactless conductivity detection (C4D) was applied as an online measurement tool for porous polymer layer growth within fused silica capillaries. The relationship between effective capillary diameter and C4D response was investigated for two polymers, butyl methacrylate-ethylene dimethacrylate (BuMA-EDMA) and polystyrene-divinylbenzene (PS-DVB) over a range of capillary diameters and layer thicknesses. The described technique can be used with both thermal and photo-initiated approaches for monoPLOT fabrication and provides an accurate, real-time measurement of the porous layer growth within the capillary, which should vastly improve column-to-column reproducibility. The technique was shown to be very precise, with a measured %RSD < 10%.
منابع مشابه
Controlled ultraviolet (UV) photoinitiated fabrication of monolithic porous layer open tubular (monoPLOT) capillary columns for chromatographic applications.
An automated column fabrication technique that is based on a ultraviolet (UV) light-emitting diode (LED) array oven, and provides precisely controlled "in-capillary" ultraviolet (UV) initiated polymerization at 365 nm, is presented for the production of open tubular monolithic porous polymer layer capillary (monoPLOT) columns of varying length, inner diameter (ID), and porous layer thickness. T...
متن کاملIn Situ Measurement of Polymer Layer Thickness in Porous Layer Open Tubular (PLOT) Columns Using Optical Absorbance in the Near-IR Range
Highly reproducible fabrication of porous layer open tubular (PLOT) structures in fused silica capillaries is often challenging; thus, methods to measure layer thickness growth in real time represent a powerful tool for the production of such columns. The work presented herein demonstrates the application of optical absorbance in the near-infrared (near IR) range for the in-process measurement ...
متن کاملUse of contactless conductivity detection for non-invasive characterisation of monolithic stationary-phase coatings for application in capillary ion chromatography.
A capacitively-coupled contactless conductivity detector (C4D) has been utilised as an on-capillary detector within a capillary ion chromatograph, incorporating a reversed-phase monolithic silica capillary column semi-permanently modified with a suitable ionic surfactant. The monolithic capillary column (150 x 0.1 mm i.d.) was modified using sodium dioctyl sulfosuccinate (DOSS), an anionic surf...
متن کاملAccurate non-invasive determination of pKa of surface functionalised ion exchange monoliths using capacitively coupled contactless conductivity detection.
The use of on-column capacitively coupled contactless conductivity detection for the accurate non-invasive visualisation of the pH dependence of covalently bound boronic acid groups within a monolithic polymeric capillary column is demonstrated.
متن کاملThe use of scanning contactless conductivity detection for the characterisation of stationary phases in micro-fluidic chips.
The use of scanning capacitively coupled contactless conductivity detection for the evaluation of the structural homogeneity and density of both packed and monolithic stationary phases in micro-fluidic chips is presented here for the first time.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Analyst
دوره 138 9 شماره
صفحات -
تاریخ انتشار 2013